Walk Test - Bosch wLSN System Reference Manual

Wireless local securitynetwork
Table of Contents

Advertisement

24
en | wLSN Devices
5.3.2

Walk Test

NOTICE!
To maximize battery life, the LED elements do not activate
unless the detector is in the Walk Test mode.
Perform a walk test to determine the boundaries of the
coverage area.
You can start a walk test from from the control panel or from
the detector.
Detected motion within the detector's coverage area activates
the red LED, transmits a signal to the control panel, and
restarts a 90-sec timer. If no motion occurs within 90 sec, the
red LED flashes for the last 10 sec to indicate that the Walk
Test mode is ending. Detected motion restarts the 90-sec timer.
1.
Figure 5.5 Walk Test
LED Color
Red – fast flash
Red – lights for 4 sec
Table 5.6 PIR Walk Test LED Indications
F01U138553 | 01 | 2010.05
Control Panel: Enter the appropriate command sequence
at the control panel to start the Walk Test mode (refer to
the control panel's documentation).
Detector: Slide open and then close the detector cover to
start a 90-sec walk test.
Start at the pattern's expected boundary and walk across
the pattern, moving closer to the detector at each pass
while observing the LED. Refer to Figure 5.5.
Refer to Table 5.6, Page 24 for PIR LED indications, and to
Table 5.7, Page 25 for dual motion LED indications.
System Reference Guide
Function
Power-up (Walk Test disabled)
Alarm, motion detected
Bosch Security Systems, Inc.
wLSN

Advertisement

Table of Contents
loading

Table of Contents