3 Mounting the terminal

3.3 Wiring the terminals and the components

NOTICE
Dommages matériels dus à un branchement incorrect de l'appareil
Tout branchement incorrect peut endommager l'appareil.
Les branchements électriques doivent se faire hors tension.
u
Ne pas modifier les ponts enfichables (cavaliers) et les commutateurs DIP lorsque l'appareil est
u
sous tension.
Connecting the power supply
Power can be supplied to the terminal via:
1
18 to 24 V AC/DC power supply unit
2
PoE device IEE 802.3at of power class 4 (up to 25.4 W)
3
Connection to 230 V AC (optional) via an internal power supply unit
Terminals in an AT housing can only be connected to 230 V AC or 110 V AC.
To connect the terminal:
1. Connect the power supply
© 2022 Interflex Datensysteme GmbH | IF-4735 Time Recording Terminal | 04.22
1
COM +
COM -
+ VCC
SH
- Tx
+ Tx
BAT
- AC
+ AC
2
3
PE
- AC
+ AC
PE
N
L
11