  • Page 1 Terminal IF-5835 Time Recording Terminal 00-5835-04xx...
  • Page 2: Table Of Contents

    Table of contents General information......................Short description....................... Scope of delivery ...................... Target group ......................Intended use ......................Safety........................Abbreviations ......................Cable lengths and cable types.................. System overview........................Mounting the terminal ......................Installation site ......................Fastening the back panel of the housing ..............Mounting and connecting the PoE connector ............
  • Page 3 Tools ......................... 21 Configuring PKI and TLS ..................25 Technical specifications ..................... 26 Disposal ..........................27 Declarations of conformity ....................28 UK Declaration of Conformity ................... 28 EU Declaration of Conformity ................... 28 © 2022 Interflex Datensysteme GmbH | IF-5835 Time Recording Terminal | 07.22...
  • Page 4: General Information

    1 General information 1 General information 1.1 Short description The IF-5835 terminal includes the following functions: Contactless identification and data recording Integration in 10/100 MB Ethernet networks Power supply via PoE (Power over Ethernet) or with 18 - 24 V low-voltage Intuitive operation and clear user feedback via touch display ...
  • Page 5: Safety

    1 General information 1.5 Safety WARNING Danger to life due to electric shock People can be seriously hurt or killed through physical contact with live parts (e.g. 230 V~). Make sure that you cannot touch live lines during installation. Switch off the power supply of the devices. Please observe the applicable safety regulations and take all precautionary measures to ensure safe installation.
  • Page 6: Cable Lengths And Cable Types

    1 General information NO contact Normally open contact Power over Ethernet RFID Radio-Frequency Identification Shield Secure shell 1.7 Cable lengths and cable types Cable function Max. length Recommended cable type 230 V AC power supply to power supply unit (if not NYM 3 x 1.5 mm pre-installed) Network cable: RJ45 patch cable, preferably...
  • Page 7: System Overview

    2 System overview 2 System overview Host system IF5835 terminal External power supply (optional) with PoE device: Switch or power injector mounting rail power supply unit and fuse protection 3 Mounting the terminal 3.1 Installation site NOTICE Damage due to the manipulation of the terminal Manipulation of the terminal can lead to data loss.
  • Page 8: Fastening The Back Panel Of The Housing

    3 Mounting the terminal  Installation site Please observe the following recommendations: Permitted ambient conditions for the device Minimum distance of 10 cm between the connecting cables and the nearest power cable Installation height 1200 mm Minimum distances between RFID and BLE devices If several RFID devices are mounted too close together, mutual interference may occur.
  • Page 9 3 Mounting the terminal Threaded bolt for securing the PoE Threaded bushing for fastening an connector optional I/O controller board (75-700-0141) Bore holes for mounting via appliance Plain washer case Flush box Fastening the back panel of the housing directly to the wall ...
  • Page 10: Mounting And Connecting The Poe Connector

    3 Mounting the terminal 3.3 Mounting and connecting the PoE connector Back panel of housing Network cable Screws for fastening the PoE connector Flat conductor cable to the back panel of the housing 1. Screw the PoE connector to the threaded bolt on the back panel of the housing using both screws provided .
  • Page 11: Initial Operation

    4 Initial operation 4 Initial operation  From a technical point of view, the terminals have an integrated controller. That is why the term Controller will be used in this section. Prerequisites ü Service IF6040 Pki Service installed ü IF6040 Tls Proxy service installed ü...
  • Page 12 4 Initial operation 5. Start communication with Open 6. Log in with username fieldservice 7. Specify a password  Details on valid password requirements and how to change a password can be found underUsers and passwords [} 17]. Only after entering a password are the network services started and the network connection can be established.
  • Page 13: Configuring The Controller In If-6040

    4 Initial operation 4.2 Configuring the controller in IF-6040 In IF-6040 under  Access > Access management > Controller: 1. Select Interflex CHP under Options in the Transmission protocol field 2. Enter the serial number of the controller under Connections. 3. Select a suitable Configuration under Connections >...
  • Page 14: Connecting Components

    4 Initial operation 7. Enter the URL of the TLS server 8. Enter registration password (nonce) 4.4 Connecting components Connecting the component to the controller 1. Make a note of the components’ serial number 2. Use the WinSCP tool to connect the controller via the network 3.
  • Page 15: Further Information For Initial Operation

    5 Further information for initial operation 5 Further information for initial operation 5.1 Restarting the controller Some changes require a restart of the controller. You can do this directly on the controller or with the appropriate commands via the console. RUN LED DIP switch Reset button...
  • Page 16 5 Further information for initial operation Cold boot All settings made on the controller via IF-6040 or OC Task are deleted or reset to default. System or operating system settings, such as the IP address or password, are retained.  Use the cold boot during initial operation and in the event of malfunctions that cannot be remedied by other means, e.g., a warm boot.
  • Page 17: Users And Passwords

    5 Further information for initial operation 4. Reset switch position: Associated console command: factory-reset full 5.2 Users and passwords The default user is fieldservice. A dialog is presented after the first login to specify the password for this user. Login to the controller and specify the password Prerequisites for a valid password Minimum 8 characters in length Contains upper and lowercase letters and numbers...
  • Page 18 5 Further information for initial operation  For a controller with the serial number 123456, the log files have the following names: cloudreadyd-123456.log service-app-mgr-123456.log The maximum size of the log files is 5 MB. If the file size is reached: The current log file is renamed: <service-name>-<controller-hostname>.<Number of backup>.log New log file with the original name is created.
  • Page 19: Checking And Setting Network Parameters

    5 Further information for initial operation Command Result Track log entries (not in backups) Shows the last 10 lines of the current log file of the cloudreadyd showlog -f service and from there every additional line Shows the last 10 lines of the current log file of the service-app- showlog -s -f mgr service and from there every additional line View the log file...
  • Page 20 5 Further information for initial operation Restoring the default IP address You have the option of restoring the default IP address if you can no longer reach the controller after changing the IP address. Perform a factory reset. Further information can be found in the section Restarting the controller [} 15]. Static IP address 1.
  • Page 21: Relevant Configuration Files

    5 Further information for initial operation 2: DHCP Select a value from 1 to 2 [2]: 2 1. Select DHCP (see above) 2. Enter the host name or accept suggestion with [Enter] To apply the settings: Restarting the controller - or – Enter nmcli-wrapper -r <connection name>...
  • Page 22 5 Further information for initial operation File > New Tls certificate Page for saving a file (certificate chain) with the customer system certificate (TLS) as the last certificate that cannot be derived further File > Page for importing a backup copy of the customer Import custom system certificate system certificate;...
  • Page 23 5 Further information for initial operation Custom system Password of the derived customer system certificate certificate key Custom system Path to the customer system certificate certificate Computer name for Tls Name of the computer with the service IF6040 Tls Proxy Additional computer Fallback computers.
  • Page 24 5 Further information for initial operation Import certificates To import certificates button Tool for checking the certificate chain You can get more information on the certificates, e.g., by using the mmc.exe operating system tool. To this end, you need the snap-in for certificates. Installing snap-in Install the snap-in as follows: 1.
  • Page 25: Configuring Pki And Tls

    5 Further information for initial operation 5.7 Configuring PKI and TLS The files for both IF6040 Pki Service and IF6040 Tls Proxy services are located in the IF6040\CommunicationSecurity\... subfolder of the installation path.  C:\Program Files\Interflex\IF6040\CommunicationSecurity\... (even if you chose the suggested 32-bit path during installation). Configuration Configuring the TLS service ...
  • Page 26: Technical Specifications

    6 Technical specifications 3. Enter the address under which the IF6040 Pki Service can be reached. 4. Enter the address under which the relevant IF6040 Peripherals Server [Id] service can be reached.  Enable the ports in the firewall. You can also see the addresses when starting, e.g., the service via the “DOS box”.
  • Page 27: Disposal

    7 Disposal Read range RFID 40 cm, BLE optional Display Capacitive 4.3 inch color display; resolution of 480 x 272 pixels Keypad IF-5735: PIN entry possible Signaling Audible: Buzzer Visual: Color LEDs Data interfaces Ethernet network connection with SSH TTL service interface General data Degree of protection IP30 (with concealed wiring)
  • Page 28: Declarations Of Conformity

    The original manual is in German. Other languages are translations of the original manual. Version: 07.22 Interflex Datensysteme GmbH +49 711 1322 - 0 Epplestraße 225 (Haus 3) interflex.info@allegion.com 70567 Stuttgart, Germany www.interflex.com © 2022 Interflex Datensysteme GmbH | All specifications are subject to change without notice.