Cisco ONS 15454 SDH User Manual page 19

Multiservice provisioning platform, chapter 15, performance monitoring
Hide thumbs Also See for ONS 15454 SDH:
Table of Contents

Advertisement

Chapter 15
Performance Monitoring
Unlike the E-Series, the G Series card does not have a display of Trunk Utilization statistics, because the
Note
G-Series card is not a Layer 2 device or switch.
15.5.2.3 G-Series Ethernet History Window
The Ethernet History window lists past Ethernet statistics for the previous time intervals. Depending on
the selected time interval, the History window displays the statistics for each port for the number of
previous time intervals as shown in
page
Table 15-20 Ethernet History Statistics Per Time Interval
Time Interval
1 minute
15 minutes
1 hour
1 day (24 hours)
15.5.3 ML-Series Ethernet Card Performance Monitoring Parameters
CTC provides Ethernet performance information for line-level parameters and historical Ethernet
statistics. The ML-Series Ethernet performance information is divided into the Ether Ports and Packet
over SONET/SDH (POS) Ports tabbed windows within the card view Performance tab window. The
following sections describe PM parameters provided for the ML100T-12 and ML1000-2 Ethernet cards.
15.5.3.1 ML-Series Ether Ports Window
The Ether Ports window lists Ethernet PM parameter values for each Ethernet port on the card.
Auto-Refresh sets a time interval at which automatic refresh will occur. The PM values are a snapshot
captured at the time intervals selected in the Auto-Refresh field. Historical PM values are not stored or
displayed.
Table 15-21
Table 15-21 ML-Series Ether Ports PM Parameters
Parameter
Rx Bytes
Rx Packets
Rx Unicast Packets
Rx Multicast Packets
Rx Broadcast Packets
Rx Giants
Rx Total Errors
April 2008
15-17.
Number of Intervals Displayed
60 previous time intervals
32 previous time intervals
24 previous time intervals
7 previous time intervals
defines the ML-Series Ethernet card Ether Ports PM parameters.
15.5.3 ML-Series Ethernet Card Performance Monitoring Parameters
Table
15-20. The listed parameters are defined in
Meaning
Number of bytes received since the last counter reset.
Number of packets received since the last counter reset.
Number of unicast packets received since the last counter reset.
Number of multicast packets received since the last counter reset.
Number of broadcast packets received since the last counter reset.
Number of packets received that are greater than 1530 bytes in
length.
Total number of receive errors.
Cisco ONS 15454 SDH Reference Manual, R4.6
Table 15-18 on
15-19