INSTA L L AT I O N I NST RU CTI ONS

4.1.28 Set reader output format

4.1.28.1 Set facility code
60, (0-255)#, default value is 0, set facility code.
Note: When the key output format is a multi key buffer output, the facility code will be used, See the following sections for
specific selections
4.1.28.2 Set D0 & D1 output format
61, 0#, D0 & D1 output wiegand format.
61, 1#, D0 output RS232-TTL-HEX format.
61, 2#, D0 output RS232-TTL-ASCII-8 format
61, 3#, D0 output RS232-TTL-ASCII-10 format.
Note: The wiegand format is an international protocol for access control products. But the width of pulse and interval time
are different. Our standard: Pulse's high level is 5V and low level is 0V. Width is 40uS, interval time is 2mS.
RS232-TTL-HEX format refers to the standard RS232 communication protocol data output, TTL level 0-5V, the output data is
output by the card byte HEX format.
The output RS232-TTL-ASCII-8 format is the output data is ASCII character format, card number data is 8 bit format, and
same as the ordinary EM card marked on the 8 bit card number, but omit the 0 in front of it.
The output RS232-TTL-ASCII-10 format is the output data is ASCII character format, card number data is 10 bit format, and
same as the ordinary EM card marked on the 10 bit card number, but omit the 0 in front of it.
For example, a 3 byte number of RS232-TTL-HEX format is A83EF6, the actual output is A83EF6, the RS232-TTL-ASCII-8 format
is 168,16118, the actual output is 16816118, the RS232-TTL-ASCII-10 format is 0011026166, the actual output is 11026166.
4.1.28.3 Set wiegand output format for reading card
62, (26-66)#, default value is 26, the Wiegand output format for reading card can be set from 26-66.