Lavry Savitr AD-24-200 Manual page 9

Table of Contents

Advertisement

1.
EDIT
control section
Enable switch
To switch between OPERATION and EDIT mode, press and hold this switch until the ENABLE lamp changes.
In EDIT mode the unit will automatically exit to OPERATION mode after a short idle time.
Enable
lamp
EDIT mode: ON
OPERATION mode: OFF
Set
switch
This switch executes all changes to audio settings. If SET is not pressed before exiting to OPERATION
mode, then all changes will not be executed and the display will revert to the previous settings.
2.
MAIN
and
3.
AUX
control sections
These two sections control clock sources. The control method of each section is identical.
MAIN or AUX switch
Each momentary press selects the next available Sample Frequency option of INTERNAL clock mode.
Each sustained press selects the next available clock mode (INTERNAL, NARROW, WIDE LOCK).
Sample Frequency is automatically detected and selected in EXTERNAL clock modes.
When both MAIN and AUX are set to Internal and to the same Sample Rate, all digital audio sample
frequency processing is bypassed for the AUX output.
EXT
lamp
OFF: INTERNAL clock mode.
ON: EXTERNAL clock mode (NARROW or WIDE LOCK).
Long flash- Pressing Set will select EXTERNAL clock mode (NARROW or WIDE LOCK).
Short flash- Pressing Set will select INTERNAL clock mode.