2.
ANALOG INPUT
section
A.
LEFT
Input connector
B.
RIGHT
Input connector
These 2 locking female XLRs accept Balanced or Unbalanced analog audio signals.
The internal GAIN range: 0 dB to 7 dB
To achieve Full-scale; balanced input range: 17-24 dBu
To achieve Full-scale; unbalanced input range: 17-20 dBu
3.
MAIN EXT SYNC INPUT
This section allows the user the option to synchronize the digital audio of the unit to an external clock source
with a sample frequency in the range of 32-200 kHz.
A.
WORD CLOCK INPUT
This BNC input is internally terminated by 75Ω.
B.
SOURCE
toggle switch
UP position: The unit can sync to the WORD CLOCK signal on the BNC.
DOWN position: The unit can sync to the AES signal on the XLR.
C.
AES INPUT
This locking female XLR enables sync to an AES digital audio signal.
4.
MAIN OUTPUT
section
A.
WORD CLOCK OUTPUT
This BNC outputs a clock source signal.
B.
OUTPUT FORMAT
Use this switch to set the digital audio OUTPUT FORMAT
UP position : OUTPUT FORMAT = AES
DOWN position : OUTPUT FORMAT = SPIDF
C.
Digital Audio Output connector
This locking male XLR is the main digital audio output.
section
connector
connector
connector
switch
5