3. ELECTRONIC COMPONENTS

Electronic components
The UVpro V-LAB Recirculating Air Disinfection System has a high-quality ballast (10) for optimum
operation of the UVpro tube. In this way maximum power, high frequent ignition and high durability
can be guaranteed. The high-frequency technology ensures a very high efficiency and low power
consumption. Of course, all components are in conformity with the "Low Voltage Directive" and "EMC
directive".
If a tube has a malfunction or in case of a defect in the wiring to or in the tube socket the ballast
automatically switches the connected tube off. Thus, the circuit board will be protected and a
malfunction can be detected by our monitoring units. The temperature of the square tube with the
fully encapsulated ballast is a maximum of 35 °C (at room temperature). The optimum temperature is
between 0 °C and +40 °C. Heating to 70 °C in a short term is possible but leads to a momentary power
loss and permanently accelerates the aging of the system.

Connection directly or with UVpro monitoring unit

- Connection with the grid
- UVpro CU1
- UVpro UVC-Line 8/16/24
orca GmbH
230 V
. The protection of the connection via a residual current
±10 %
AC
circuit breaker (30 mA) is mandatory.
The optional monitoring unit CU1 can be used for one UVpro device. You
will find further information in the documentations of this monitoring
unit.
The optional monitoring unit UVC-Line 8/16/24 can be used for several
UVpro devices. Further information can be found in the documentations
of this monitoring unit.