HP Kayak XU03 User Manual page 14

Pc workstations
Hide thumbs Also See for Kayak XU03:
Table of Contents

Advertisement

Test
The BIOS then executes the Power On Self Test
(POST) sequence. In this phase, HP MaxiLife
waits for any error messages that the BIOS may
issue.
During normal usage of the PC, HP MaxiLife is
always checking vital parameters of the system.
If an error should occur, a message would be
automatically displayed on the LCD panel.
1.
Special cases: Board PLL = System board needs replacing. CPU error = Reset or power off the system to recover.
Special Cases
HP MaxiLife Utility
Error Code
POST XXXX
TEMP IO SLOT
If a CPU is not installed correctly.
1
Either the "Power CPUx" or "CPU socket" or "BIOS" message may
appear. This will depend on which end of the CPU connector is not
correctly inserted.
If a VRM is installed and there is a terminator in the associated
2
CPU socket.
MaxiLife displays "Power" error message and the system does not
start
Only one pre-boot error reported on the system.
3
Hidden errors will be revealed when the current error has been
fixed.
If a "No Video Error" message is displayed, even though the video
4
is working correctly.
With some specific add-on boards (for example, 1540 from
Adaptec with SCSI BIOS), this error may appear while the system
is fully working. To check if this is the case, remove all add-on
boards from the basic system configuration.
14
Action to Take
• If the screen is working, you can obtain the signification of the
error by typing "Enter" at the end of the POST. Or, you can
check the list of errors that are available on the HP World-Wide
Web support page.
• Check the connection of the corresponding component, which
could be: "Temp IO slot", "Power errors, "Fan CPU", "Board
PLL", "Temp disk", "Temp CPU", "Fan disk", "Fan IO slot", "CPU
1
error".