10-2-10 Compressor starting error
Indoor display
3 LED DISPLAY
LED1
Outdoor display
: LAMP ON
1. Checklist :
1) Is the connection of cable for the compressor?
2) Is the compressor wire is connected clockwise? U(RED)-V(BLU)-W(YEL)
3) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
76
SAMSUNG ELECTRONICS
SERVICE MANUAL_EU_INV_Wind Free.indd 76
7 SEG DISPLAY
LED2
LED3
Comp starting error
: LAMP OFF
: LAMP BLINK
Restart after power
.
Is the restart error occurred again?
YES
Is the connection of compressor wire is normal?
YES
Download the EEPROM data
Is the restart error occurred again?
YES
Is the compressor body and interphase
resistance insulated?
YES
Exchange the compressor
E461
Comp starting error
NO
Terminate the service
NO
Connect the comp wire normally
NO
Terminate the service
NO
Exchange the Outdoor PBA