red lion C48TS004 Instruction Manual

1/16 din timer

Advertisement

Quick Links

Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution
of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business
relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components
to meet their specific needs.
With the principle of "Quality Parts,Customers Priority,Honest Operation,and Considerate Service",our business
mainly focus on the distribution of electronic components. Line cards we deal with include
Microchip,ALPS,ROHM,Xilinx,Pulse,ON,Everlight and Freescale. Main products comprise
IC,Modules,Potentiometer,IC Socket,Relay,Connector.Our parts cover such applications as commercial,industrial,
and automotives areas.
We are looking forward to setting up business relationship with you and hope to provide you with the best service
and solution. Let us make a better world for our industry!
Contact us
Tel: +86-755-8981 8866 Fax: +86-755-8427 6832
Email & Skype: info@chipsmall.com Web: www.chipsmall.com
Address: A1208, Overseas Decoration Building, #122 Zhenhua RD., Futian, Shenzhen, China
  

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C48TS004 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for red lion C48TS004

  • Page 1 Chipsmall Limited consists of a professional team with an average of over 10 year of expertise in the distribution of electronic components. Based in Hongkong, we have already established firm and mutual-benefit business relationships with customers from,Europe,America and south Asia,supplying obsolete and hard-to-find components to meet their specific needs.
  • Page 2 THE 1/16 DIN TIMER MODEL C48T INSTRUCTION MANUAL...
  • Page 3 Red Lion Controls the leader in today’s industrial market. Red Lion Controls has a complete line of industrial indication and control equipment, and we look forward to servicing you now and in the future.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS GENERAL DESCRIPTION................................1 Safety Summary..................................1 Block Diagram ..................................2 INSTALLATION & CONNECTIONS...............................3 Multiple Unit Stacking ................................3 Mounting Instructions ................................4 Unit Removal Procedure ................................4 Removing Unit Assembly ................................4 Installing Unit Assembly ................................4 Output Board ...................................5 Replacing Relay Output Board ............................5 EMC Installation Guidelines ..............................6 Wiring Connections .................................6 AC Versions (C48TXX0X)..............................7...
  • Page 5 TABLE OF CONTENTS (Cont’d) Programming Menu................................13 Numeric Value Entry Method ............................13 Timer Range ..................................13 Timer Operating Mode ..............................13 Timer Reset at Power-up..............................17 Access Preset Values ..............................17 Preset 1 Value .................................17 Preset 2 Value (Dual Preset Model only) ........................17 Preset 1 Track Preset 2 (Dual Preset Model only) ......................17 Access Output Time Values.............................18 Output Resolution ................................18 Output 1 Time Value ................................18...
  • Page 6 TABLE OF CONTENTS (Cont’d) Receiving Data ..................................26 Terminal Emulation Program For IBM® PC ...........................27 Serial Connections .................................27 Terminal Descriptions ..............................27 Connecting To A Host Terminal ............................28 Troubleshooting Serial Communications..........................29 APPENDIX “A” - APPLICATION EXAMPLE ..........................30 APPENDIX “B” - SPECIFICATIONS AND DIMENSIONS ......................31 APPENDIX “C”...
  • Page 8: General Description

    GENERAL DESCRIPTION The Model C48 Timer is available in Single or Dual Preset models. The The Timer can also be configured to Continue or Stop timing upon reaching C48T features a 7 segment, 2 line by 6 digit reflective or backlit LCD display. Preset.
  • Page 9: Block Diagram

    BLOCK DIAGRAM Figure 1, Block Diagram...
  • Page 10: Installation & Connections

    INSTALLATION & CONNECTIONS The C48 Timer meets NEMA 4X/IP65 requirements for indoor use to provide a watertight seal in steel panels with a minimum thickness of 0.09 inch, or aluminum panels with a minimum thickness of 0.12 inch. The units are intended to be installed into an enclosed panel. The complete unit assembly (i.e.
  • Page 11: Mounting Instructions

    Mounting Instructions 1. Prepare the panel cutout to the dimensions shown in Figure 3, Multiple Unit Stacking. 2. Remove the panel latch from the unit. Discard the cardboard sleeve. 3. Carefully remove the center section of the panel gasket and discard. Slide the panel gasket over the unit from the rear, seating it against the lip at the front of the case.
  • Page 12: Output Board

    Output Board The C48T is supplied with an output board installed. The output board is preconfigured for the type of output needed, based upon the Model ordered. See Ordering Information, page 35, for available models. All relay output boards are field replaceable.
  • Page 13: Emc Installation Guidelines

    core several times or use multiple cores on each cable for additional EMC INSTALLATION GUIDELINES protection. Install line filters on the power input cable to the unit to suppress Although this unit is designed with a high degree of immunity to power line interference.
  • Page 14: Ac Versions (C48Txx0X)

    POWER WIRING 1. The terminal may be used as a +12 VDC output for sensor power. In this case, the PNP output voltage level will be +12 VDC (±15%). A maximum AC Versions (C48TXX0X) of 100 mA is available for the combination of sensor current and PNP AC Power Wiring output sourcing current.
  • Page 15: User Input Plug Jumper

    User Inputs Program Disable Plug Jumper The three external user inputs are programmable inputs that can be The program disable plug jumper is used to enable and disable front panel configured as current sinking (active low) or current sourcing (active high) programming of the C48T.
  • Page 16: Front Panel Description

    FRONT PANEL DESCRIPTION The front panel bezel material is flame and scratch resistant, textured plastic with clear viewing window that meets NEMA 4X/IP65 requirements, when properly installed. Continuous exposure to direct sunlight might accelerate the aging process of the plastic material used in the bezel.
  • Page 17: Basic Operation

    BASIC OPERATION Normal Operating Mode In the normal operating mode, the timer value is shown on the main display. By successively pressing the key, the accessible presets or output time values can be viewed in the secondary display. Each of these values can be independently programmed to be viewable only, viewable and changeable, or locked (not viewable) in the normal operating mode.
  • Page 18: Front Panel Accessible Functions With Program Disable

    Front Panel Accessible Functions With Program Disable There are several ways to limit the programming of parameters from the front to be entered, depending on the Program Disable Setting. Front Panel Function panel keypad. The Accessible Value parameter is used with the Program Disable Key F1 cannot be selected for program disable.
  • Page 19: Programming General Description

    PROGRAMMING GENERAL DESCRIPTION Programming of the C48T is done through the front panel keypad. English Digit Entry language prompts, flashing parameter values, and the front panel keypad aid the If the preset entry method has been set to “digit entry”, the least significant operator during programming.
  • Page 20: User Interface/Programming Modes

    USER INTERFACE/PROGRAMMING MODES The operating modes of the C48T are programmed using the front panel Timer Operating Mode keypad. (See page 12, for details on using the keypad to program the unit) OPEr Accessibility to the Programming Menu depends on the Program Disable The charts on the following pages, show operating Function setting (See page 11, for available program disable settings).
  • Page 21 Output 1: (Main Output for Single Preset Model) O1 Off at O2: (Dual Preset only) Latched - When Output 1 activates it stays activated or latched until it is Output 1 activates at Preset 1. It deactivates when Output 2 is activated. manually reset.
  • Page 22 DUAL PRESET OPERATING MODES Use either of the two charts on the next two pages for more information on specific operating modes. DUAL PRESET OPERATING MODES MODE# RESET TYPE RESET OUTPUT 1 OUTPUT 2 Continue Timing at 02, Manual Reset to Zero, Latched Outputs Continue Timing at 02, Manual Reset to Zero, 01 Timed, 02 Latched Continue Timing at 02, Manual Reset to Zero, 01 and 02 Timed Continue Timing at 02, Manual Reset to Zero, 01 off at 02, 02 Latched...
  • Page 23 MODE# RESET TYPE RESET OUTPUT 1 OUTPUT 2 DUAL PRESET OPERATING MODES Stop Timing at 02, Manual Reset to Zero, Latched Outputs Stop Timing at 02, Manual Reset to Zero, 01 Timed, 02 Latched Stop Timing at 02, Manual Reset to Zero, 01 and 02 Timed Stop Timing at 02, Manual Reset to Zero, 01 off at 02, 02 Latched Stop Timing at 02, Manual Reset to Zero, 01 off at 02, 02 Timed Stop Timing at 02, Manual Reset to Preset 2, Latched Outputs...
  • Page 24: Timer Reset At Power-Up

    Timer Reset at Power-up Preset 1 Value rSt. P . u P PrESEt This parameter determines whether or not the timer is The Preset 1 value is used to control the activation of 1. 0 reset when power is applied to the unit. Output 1.
  • Page 25: Access Output Time Values

    Single Preset Access Output Time Values Output 1 Time Value OutPut Model This parameter configures the type of access given to The Output 1 Time Value controls the Output 1 duration, 0. 1 0 Ac Out OPEr each Output Time Value when in normal operating mode when Output 1 is set for timed mode of operation ( and at Program Disable Level 1.
  • Page 26: Reverse Annunciator Logic

    Single Preset Reverse Annunciator Logic User Inputs Model This parameter controls the logic state of the Output Three external User Inputs plus the front panel function key are available on rEVAnu Display Annunciators (‘01’ and ‘02’). the C48 Timer. The parameter list below shows all available user input functions.

Table of Contents