Instanta WMS6TF Installation And User Instructions Manual

Instanta WMS6TF Installation And User Instructions Manual

Sureflow touch-free

Advertisement

Quick Links

SureFlow Touch-Free
Model: WMS6TF
(DB600-WTF)
Auto-Fill, Wall Mounted Boiler with 'Touch-Free' Dispense
INSTALLATION AND USER INSTRUCTIONS
Zip Water (UK) Ltd
Trafalgar House, Rash's Green, Dereham, Norfolk, NR19 1JG
Tel: (0345) 600 5005
IB91 – (ISS: 01)

Advertisement

Table of Contents
loading

Summary of Contents for Instanta WMS6TF

  • Page 1 SureFlow Touch-Free Model: WMS6TF (DB600-WTF) Auto-Fill, Wall Mounted Boiler with ‘Touch-Free’ Dispense INSTALLATION AND USER INSTRUCTIONS Zip Water (UK) Ltd Trafalgar House, Rash’s Green, Dereham, Norfolk, NR19 1JG Tel: (0345) 600 5005 IB91 – (ISS: 01)
  • Page 2: Table Of Contents

    Your new water boiler is designed to give you years of trouble-free service provided that the instructions contained in this manual are followed. All new series Instanta products are energy efficient, simple to operate and easy to service. Find out more about Instanta products at...
  • Page 3: Safety & Environmental Information & Delivery Check-List

    SAFETY INFORMATION Please read the following carefully before starting work on this equipment. A competent person should install this appliance in accordance with the installation instructions for this appliance and all relevant local and national standards including the following: Health & Safety at Work Act IEE Regulations Local &...
  • Page 4: Technical Specification And Features & Benefits

    TECHNICAL SPECIFICATION Model: DB600-TFW (WMS6TF) Width: 340 mm Height: 478 mm Depth: 260 mm Power Rating: 3.0 Kw Weight-Empty: 9.8 KG Weight-Full: 18.5 KG Water Inlet Pressure: 2 to 7 Bar FEATURES & BENEFITS • Touch-Free Dispense (Smart Sensor activated) – avoids cross infection.
  • Page 5: Electrical Connection

    Position the boiler so that the tap is approximately 400mm above a draining board. Leave sufficient space around the unit to enable access for servicing, paying particular attention to the position of the top-centre fixing screw that holds the case in place. When mounting on wall…screw in the top two screws leaving about 6mm protruding and hang the machine using the keyhole slots provided.
  • Page 6: Overflow/Drain

    Water purification filters are available from Instanta to ensure fresh tasting water. In hard water areas, scale can cause problems. Fitting a scale reducer will help minimise scale but will not eliminate scale completely. NOTE: To avoid damage to the appliance, do not use any solder connections whilst pipes are connected to the boiler.
  • Page 7: Fitting Case

    e) FITTING CASE: Attach the Earth wire connection to bottom of stainless steel boiler-case using M4 screw & washer supplied. Position the case close to the wall-mounted boiler and plug-in the FOUR communications- leads: 1) From LCD screen to main circuit board (white cable with 6-pin plug) 2) From circular Sensor-PCB to small circuit board (black cable –...
  • Page 8: Optional Timed Dispense (With Top-Up Facility)

    OPTIONAL “TIMED” DISPENSE: This function is appropriate when the cup/teapot being filled is always the same size/capacity. To change boiler from “on-demand” default setting to “Timed” dispense: 1) Place vessel on spill-tray, within cup aperture (breaking safety light-beam). 2) Switch off on front of unit 3) Isolate from mains power supply and wait 10 seconds.
  • Page 9: Optional Filter Monitor

    If in doubt as to the hardness of water supplied in your area, consult your local water authority PREVENTATIVE MAINTENANCE: AQ35/KIT – The Instanta AQ35 high-flow multi-filter delivers the best quality of water by removing sediment and impurities such as chlorine. The filter also reduces scale build-up which results in lower running costs, improved energy efficiency and longer life expectancy.
  • Page 10: Maintenance, Spares & Service Information

    MAINTENANCE & SERVICE INFORMATION Descaling: The boiler should be periodically checked for scale build-up…see below: In hard water areas, the boiler should be descaled on a regular basis to maintain efficient operation, minimise energy consumption, and also retain the water quality. To de-scale: Isolate machine from power supply and allow to cool Remove the boiler case (2 screws)
  • Page 11: Guarantee

    SCREEN MESSAGE POSSIBLE CAUSES: ACTION; • • Water turned off Check water supply and • R E A D Y stop-cock in-coming water • CHECK WATER pressure Check in-coming water is at minimum of 2-bar WHITE SCREEN • De-scale inside of tank and •...