Your new water boiler is designed to give you years of trouble-free service provided that the instructions contained in this manual are followed. All new series Instanta products are energy efficient, simple to operate and easy to service. Find out more about Instanta products at...
SAFETY INFORMATION Please read the following carefully before starting work on this equipment. A competent person should install this appliance in accordance with the installation instructions for this appliance and all relevant local and national standards including the following: Health & Safety at Work Act IEE Regulations Local &...
TECHNICAL SPECIFICATION Model: WMS6PB (DB600-W) Width: 340 mm Height: 478 mm Depth: 260 mm Power Rating: 3.0 kW Weight-Empty: 9.8 KG Weight-Full: 18.5 KG Water Inlet Pressure: 2 to 7 Bar INSTALLATION a) POSITIONING THE UNIT The heater should be positioned in a convenient place, on a wall that is capable of supporting it safely (refer to Technical Specification above for weight of boiler).
A 15mm stop valve must be fitted between the water supply and the boiler so that it can be isolated. Water purification filters are available from Instanta to ensure fresh tasting water. In hard water areas, scale can cause problems. Fitting a scale reducer will help minimise scale but will not eliminate scale completely.
(e.g. overnight). Whilst every reasonable precaution is taken to prevent an overflow, Instanta cannot be held responsible for any damage caused as a result of incorrect installation or blockage of the overflow or failure to direct the overflow to a safe outlet.
OPERATION First use (once water and electrical connections have been made); Switch the power and water supply on. Screen will light up Red and will run through an initial self- diagnostic check before starting to fill with water (screen reads; “NOT READY FILLING”). Once primed with water, the boiler will begin to heat (screen reads;...
If in doubt as to the hardness of water supplied in your area, consult your local water authority PREVENTATIVE MAINTENANCE: AQ35/KIT – The Instanta AQ35 high-flow multi-filter delivers the best quality of water by removing sediment and impurities such as chlorine. The filter also reduces scale build-up which results in lower running costs, improved energy efficiency and longer life expectancy.
Page 9
MAINTENANCE & SERVICE INFORMATION Descaling: The boiler should be periodically checked for scale build-up…see below: In hard water areas, the boiler should be descaled on a regular basis to maintain efficient operation, minimise energy consumption, and also retain the water quality. To de-scale: Isolate machine from power supply and allow to cool Remove the boiler case (2 screws)
SERVICE/TECHNICAL SUPPORT & SPARES: Tel: 01704 502911 To ensure your service enquiry is handled as efficiently as possible, please have the following information available; Brief description of problem Product Type (model) Serial Number (label on under-side of boiler case). This is essential For spare parts, filters and other accessories: Tel: 01704 501114 GUARANTEE Your boiler is guaranteed for two years from date of installation.