Auto-fill catering water boiler with integrated multi-filter (12 pages)
Summary of Contents for Instanta DB500
Page 1
SureFlow Touch DB500 & DB1000 Auto-Fill Catering Water Boilers with Push Button Dispense Installation And User Instructions The Professional’s Choice INSTANTA LIMITED Canning Road, Southport, Merseyside, PR9 7SN Tel: (01704) 501114 Fax: (01704) 501115 IB90 - ISS: 01...
Page 2
Dear Customer, constant source of near boiling water, which can be dispensed for the preparation of hot drinks. Thank you for purchasing this Instanta product. • The SureFlow Touch appliances are ideal for Your new water boiler is designed to give...
Before starting installation, check that you have (28psi) NOTE: If your water pressure exceeds the following parts; 7bar, fit a suitable pressure reduction valve. • Catering Water Boiler We regret that Instanta cannot be held • Drip-tray responsible for any machine malfunctions • Drip-tray drain fitting...
Whilst every reasonable precaution is taken wait 15 minutes before starting to use. to prevent an overflow, Instanta cannot be held responsible for any damage caused as a • The boiler is now ready for use.
Regular Daily Use Optional “Timed” Dispense: Switch boiler on and wait for the screen to This function is appropriate when the cup/teapot turn white and show “READY” message and being filled is always the same size/capacity. dispense button to turn red. The water will To change boiler from “on-demand”...
Page 6
Preventative Maintenance: • Remove as much scale as possible by hand. Any scale which is difficult to remove can be AQ35/KIT – The Instanta AQ35 high-flow dissolved by using a de-scaling solution. multi-filter delivers the best quality of water by removing sediment and impurities such as •...
Page 7
Service Warnings and Fault Diagnosis Your boiler is fitted with an intelligent fault diagnosing system and is able to detect various fault conditions. Some of these are less serious and the machine will continue to operate as normal, while others are more serious and will disable the unit. Before calling for service, switch the machine off at the mains supply and then switch back on after 10 minutes.
• Accidental damage, misuse or use not in accordance with these instructions and damage caused by incorrect installation. The manufacturer disclaims any liability for incidental, or consequential damages. INSTANTA LIMITED Canning Road, Southport, Merseyside PR9 7SN Tel: (01704) 501114 Fax: (01704) 501115 IB90 - ISS:01 FM 36413...