Programming transmitter / channel
Commissioning (connection of a tubular or venetian blind motor)
Precondition: The VarioTec-868 JA/RM is installed.
(→ See Chapter connestion RM/JA)
The end positions must be set.
1. When the power supply is restored or by pressing the P-button
(min. 5 Sec) on the VarioTec-868 JA/RM , the device is ready to pro-
gramme for 5 minutes.
2. Programme the transmitter (Z see transmitter instructions).
3. To define the keyboard layout, press the UP button on the trans-
mitter as soon as the shutter/canopy/blind begins to move upwards
(after approx. 1 second).
The shutter/canopy/blind will come briefly to a halt.
Press the DOWN button on the transmitter as soon as the shutter/
canopy/blind begins to move downwards.
The shutter/canopy/blind will come to a halt.
The transmitter/channel has been successfully programmed.
Note: If more than one receiver is connected to the same mains
lead, all of these will be in programming mode simultane-
ously. The shutters/canopies/blinds will begin to move up
and down "at random". The longer you take to carry out the
programming, the larger the offset becomes.
Individual channels can now be assigned to the relevant
receiver. The brief up and down movements can be stop-
ped by pressing the STOP button on one of the pre-pro-
grammed hand-held transmitters briefly.
Channel assignment/modification can now be carried out
without you having to disconnect individual channels.
For more details, refer to the operating instructions for your
transmitter.
14 | EN
Technical data / Cleaning

Technical data

Nominal voltage
Switched current
System of protection
Protection class
(only after correct installation)
Permissible ambient temperature 0 to +55 °C
Operating frequency
Type of installation
Max. number of transmitters

Cleaning

Clean the device with a damp cloth only. Do not use a clean-
sing agent as doing so may damage the plastic.
230-240 V AC / 50-60 Hz
5 A /250 V AC bei cos j = 1
IP 20
II
868,3 MHz
Concealed: Ø 58 mm
wall-mounted
Exposed: in appropriate
exposed casing
16 transmitters
EN | 15