Programming

Adjustment to intermediate position

The shutter/curtain/blind can only be moved into the
intermediate position from the upper end limit position.
1. Press the DOWN button twice in quick succession.
The shutter/curtain/blind is adjusted into the stored
intermediate position.
Adjustment to ventilation position (roller shutters)
Roller shutters can only be moved into the ventilation position
from the lower end limit position.
1. Press the UP button twice in quick succession. The shutters are
adjusted into the stored ventilation position.
Adjustment to reverse position (venetian blinds)
The venetian blind slats must be closed before the blind can be
adjusted into the reverse position.
1. Press UP button twice in quick succession.
The venetian blind is adjusted into the stored reverse position.
When the blind reaches the stored intermediate position the blind
slats are turned automatically (provided a reverse position has
been pre-programmed).

Deleting intermediate position

1. Press and hold the Pos B programming button for more than
5 seconds. The intermediate position is now deleted.
The control light will flash 3 times briefly.

Deleting ventilation/reverse position

Press and hold the Pos V programming button for more than
5 seconds. The ventilation/reverse position is now deleted.
The control light will flash 3 times briefly.
GB-11
Technical data/Cleaning/

Troubleshooting

Technical data

Nominal voltage
Switched current
System of protection
Protection class
Permissible ambient temperature 0 to +55 °C
Type of installation

Cleaning

Clean the device with a damp cloth only. Do not use a cleansing
agent as doing so may damage the plastic.
Troubleshooting
Problem
Cause
Drive is not functioning. Faulty connection.
Drive moves in the
Faulty connection.
wrong direction.
VarioTec does not
1. Device is set to
carry out external
manual
control commands.
2. Alarm signal is active. 2. Wait until alarm

General declaration of conformity:

The company elero GmbH hereby declares that the VarioTec device
complies with the basic requirements and other relevant regulations
of the EC Directive 1999/5/EG.
230-240 V AC / 50-60 Hz
5 A /250 V AC for cos j = 1
IP 20
II
Concealed: l 58 mm wall-
mounted
Exposed: in appropriate
exposed casing
Remedy
Check connection.
Exchange V and B
wires in the power
supply unit.
1. Set the device to
mode.
automatic mode.
signal disappears
or rectify problem
causing signal.