Download Print this page

Daikin FHY71FVE Service Manual

Indoor unit heat pump

Advertisement

Quick Links

Si211307E
REMOVAL
PROCEDURE
S E R V I C E
M A N U A L
3 HP Class
Indoor Unit
Non-Inverter
Pair Type

Advertisement

loading

Summary of Contents for Daikin FHY71FVE

  • Page 1 Si211307E REMOVAL PROCEDURE S E R V I C E M A N U A L 3 HP Class Indoor Unit Non-Inverter Pair Type...
  • Page 2 Service Manual Removal Procedure Indoor Unit Applicable Models Heat Pump FHY71FVE...
  • Page 3: Table Of Contents

    Si211307E Table of Contents 1. Procedure to Remove Air Filter and Suction Grille .........2 2. Procedure to Remove Electrical Parts and PCB........3 3. Procedure to Remove Horizontal Blade..........5 4. Procedure to Remove Fan Rotor an Motor ..........6 5. Procedure to Remove Fan Bearing............8 6.
  • Page 4: Procedure To Remove Air Filter And Suction Grille

    Procedure to Remove Air Filter and Suction Grille Si211307E 1. Procedure to Remove Air Filter and Suction Grille Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points The air filter is mounted behind the suction grille.
  • Page 5: Procedure To Remove Electrical Parts And Pcb

    Si211307E Procedure to Remove Electrical Parts and PCB 2. Procedure to Remove Electrical Parts and PCB Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points ∗Remove the air filter according to the procedures for removing the air filter and suction grille.
  • Page 6 Procedure to Remove Electrical Parts and PCB Si211307E Step Procedure Points Pull open the control box and let it hang by the 2 locations in the rear. Electrical parts can now be removed. Control box Rear panel Disconnect the connector mounted on the PCB.
  • Page 7: Procedure To Remove Horizontal Blade

    Si211307E Procedure to Remove Horizontal Blade 3. Procedure to Remove Horizontal Blade Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the left side panel according to the procedure for removing the fan bearing.
  • Page 8: Procedure To Remove Fan Rotor An Motor

    Procedure to Remove Fan Rotor an Motor Si211307E 4. Procedure to Remove Fan Rotor an Motor Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Push the 2 tabs of the fan housing toward the inside with your fingers, and pull out the fan housing.
  • Page 9 Si211307E Procedure to Remove Fan Rotor an Motor Step Procedure Points Slide the intermediate bearing to the right and remove the fan rotor assy. Disconnect the 2 fan 2 connectors motor connecting Connector (1) handles high connectors. voltage (220-240 V), so be sure to turn of the power supply before Remove the 2 fan motor disconnecting.
  • Page 10: Procedure To Remove Fan Bearing

    Procedure to Remove Fan Bearing Si211307E 5. Procedure to Remove Fan Bearing Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points ∗Remove the fan rotor according to the procedures for removing the fan rotor and fan motor.
  • Page 11: Procedure To Remove Bottom Panel And Drain Pan

    Si211307E Procedure to Remove Bottom Panel and Drain Pan 6. Procedure to Remove Bottom Panel and Drain Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points ∗Remove the air filter according to its removal procedure.
  • Page 12 Procedure to Remove Bottom Panel and Drain Pan Si211307E Step Procedure Points Remove the 5 bottom panel installation screws (2 each on the left and right, 3 in the rear), and remove the bottom panel. Remove the rear surface screws (2 each on the left and right), and remove the center screw while supporting the bottom panel from...
  • Page 13 Si211307E Procedure to Remove Bottom Panel and Drain Pan Step Procedure Points Lower the front surface of (1) Lower the front surface of the the drain pan, remove the drain pan. hooking part of the rear (2) Remove the hooking part of the surface, and remove the rear surface.
  • Page 14: Procedure To Remove Swing Motor

    Procedure to Remove Swing Motor Si211307E 7. Procedure to Remove Swing Motor Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points ∗Remove the right side panel according to the procedures for removing the bottom panel and drain pan.
  • Page 15 Revision History Month / Year Version Revised contents 06 / 2013 Si211307E First edition...
  • Page 16 Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.