ACR Electronics RCL-100 LED Product Support Manual page 10

Remote control searchlight system
Table of Contents

Advertisement

Master
Controller Wire
ORANGE
BLUE
Yellow
Green
Red
White
Black
Brown
WARNING: The ORANGE wire must be fused with a 5 amp fuse
in the Master Controller's in-line fuse-holder.
Wiring to Searchlight
The RCL-100 Searchlight is supplied with a 15 foot integral wire
harness. If you must lengthen the wire harness, use the same gauge
wire to minimize the voltage drop. This is especially important for the
ORANGE lamp power (+) and BLUE (-) lamp ground wires.
Following the wiring scheme shown in Table 1, use the supplied butt
connectors to connect the Master Controller to the Searchlight.
Wiring to Point Pad™
The RG-59 Coax cable is supplied without the "F" connectors
attached for ease of routing. After the coax has been routed, strip the
insulation and crimp the "F" connectors in place. Screw the "F"
connectors to the Master Controller and the Point Pad™.
Wiring to Power Supply
The power source must be a fused 12 VDC, 5-amp supply or 24 VDC,
5-amp supply. Following the wiring scheme in Table 1, use the
supplied butt connectors to connect the Master Controller to the
Power Source. Refer to Table 2 for proper wire size for connection of
the input power lines.
Y1-03-0321C
Searchlight
Cable Wire
Yellow
Green
Red
White
Black
Brown
Table 1
Power Source
Lead
+12 VDC or +24
VDC**
(-ve) Ground
Function
Power
Ground
Lamp Power
Lamp Power
Up
Down
Right
Left