Operating Mode Description "Stairs Light Activation Relay; Relay Unit Light Activation Time - golmar SAR-GB2 User Manual

Relay unit
Hide thumbs Also See for SAR-GB2:
Table of Contents

Advertisement

RELAY UNIT TSAR-GB2
INSTALLATION
Operating mode "Stairs light activation relay":
-
This operating mode allows activation of the stairs light from the apartment.
It is activated through the push button
Vesta2
, Vesta7, Pentha
-
See user manual for telephone or monitor installed in the apartment.
-
The dip switch SW1 of the relay unit must be configured with DIP1, DIP2 and DIP3 set to OFF.
-
Maximum of one relay unit per system.
-
Note: Once the relay unit has been activated, by default it will deactivate automatically after 1 minute
Configuration:
Step
1:
Remove the power supply from the SAR-GB2 relay unit by removing the relay unit Bus connector (The power
supply status LED will turn off).
Step
2:
Connect the power supply to the SAR-GB2 relay unit by inserting the relay unit Bus connector. (LED showing
the power supply status will turn on).
Step
3:
In the first 5 seconds after connecting the power supply to the relay unit, bypass the terminals '-' and 'P' with a
cable for 3 seconds (the status LED "in use" will flash).
Step
4:
Next, bypass the terminals '-' and 'AP' with a cable for 3 seconds (the status LED "in use" will light up
continuously).
Step
5:
Bypass the terminals '-' and 'P' again. The time that the terminals '-' and 'P' are bypassed will configure the
activation time of the relay unit (every flash of the status LED "in use" is equivalent to 30 seconds of the activation
time). The maximum configurable time is 900 seconds.
Step
6:
After removing the bypass from the terminals '-' and 'P', the time that has been configured will be saved and the
relay unit will come out of time configuration mode.
Step
7:
Check that the activation time of the relay unit is correct.
Note: The relay unit by default has a configured activation time of 1 minute.
of the telephone T-562 GB2 or Nhea GB2 and from the monitor light function
or Thera.

Relay unit light activation time:

7
3
2
1
.