golmar SAR-G2+ Instruction Manual

golmar SAR-G2+ Instruction Manual

Hide thumbs Also See for SAR-G2+:

Advertisement

Quick Links

TECHNOLOGY
UNIDAD DE RELÉ
SAR-G2+
-
NC
12258965
RELE SAR-G2+
POWER
Cód. 50122550
C NA 12+
AP1
V02
CONTACTOS RELÉ /
RELAY CONTACTS
1A 18V AC
0.75A 24V DC
GOLMAR S.A.
BUS BUS
C/ Silici, 13
08940-SPAIN
TSAR-G2 E
-
JP1
3
2
1
+ N REV.0221

Advertisement

Table of Contents
loading

Summary of Contents for golmar SAR-G2+

  • Page 1 UNIDAD DE RELÉ TECHNOLOGY SAR-G2+ C NA 12+ 12258965 RELE SAR-G2+ CONTACTOS RELÉ / RELAY CONTACTS POWER 1A 18V AC 0.75A 24V DC GOLMAR S.A. BUS BUS C/ Silici, 13 08940-SPAIN Cód. 50122550 + N REV.0221 TSAR-G2 E...
  • Page 2: Table Of Contents

    O Stairs light activation relay (necessary module SAR-12/24). O Golmar additional alternating lock release relay (necessary power supply unit TF-104). - Necessary to configure operating mode of the SAR-G2 relay unit - Connects to the Bus...
  • Page 3: Operating Modes

    Additional lock release activation relay (necessary power supply unit TF-104): - This operating mode allows activation of a Golmar additional alternating lock release. This lock release is activated as lock release 1 or lock release 2 and with the panel that has been assigned (through configuration in SAR-G2 see...
  • Page 4: Description Of Sar-G2 Relay Unit

    C NA 12+ 12258965 RELE SAR-G2+ CONTACTOS RELÉ / RELAY CONTACTS POWER 1A 18V AC 0.75A 24V DC GOLMAR S.A. BUS BUS C/ Silici, 13 08940-SPAIN 12Vdc and “AP ” output connector Status LED (power supply). SW1 dip switch. Relay contact connector.
  • Page 5: Detail Of The Installation Of The Sar-G2 Relay Unit

    RELE SAR-G2+ CONTACTOS RELÉ / RELAY CONTACTS POWER 1A 18V AC 0.75A 24V DC GOLMAR S.A. BUS BUS C/ Silici, 13 08940-SPAIN The relay unit can be mounted onto a DIN rail (4 elements) by applying slight pressure. To remove the relay unit from the rail, use a flat screwdriver and lever it off, as shown in the drawing.
  • Page 6: Operating Mode Description "Lock Release Relay

    Additional lock release activation relay (necessary power supply unit TF-104): - This operating mode allows activation of a Golmar additional alternating lock release. This lock release is activated as lock release 1 or lock release 2 and with the panel that has been assigned (through configuration in SAR-G2 see...
  • Page 7: Wiring Diagrams

    Neutral point of the power supply of the stairs light is connected in series through the relay contacts of the SAR-12/24. IMPORTANT: For the description, installation, configuration and programming of the system, see the corresponding manual. Golmar additional alternating lock release relay: Pressing "AP1" activates the lock...
  • Page 8 C/ Silici, 13 08940- Cornellá de Llobregat SPAIN Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice.

This manual is also suitable for:

50122550