4.8 INPUT SIGNAL TIMINGS
4.8.1 Timing characteristics
Parameter
Frequency
CLK
Duty
Rise time, Fall time
Horizontal
DE
Vertical
CLK-DE
Rise time, Fall time
CLK-DATA
DATA
(A) to (D)
Rise time, Fall time
Note1: The sum of jitter and skew of horizontal period should be within 1 CLK.
4.8.2 Input signal timing chart
Invalid
DE
DE
CLK
DATA (A) to (D)
Symbol
1/ tc
-
-
Cycle
th
Display period
thd
Cycle
tv
Display period
tvd
Setup time
-
Hold time
-
-
Setup time
-
Hold time
-
-
tvd = 1,536H (fixed)
Invalid
Invalid
DATA SHEET DOD-PD-1318 (4th edition)
min.
typ.
60.0
65.0
See the data sheet of LVDS
transmitter.
10.34
10.34
640
672
512
15.47
16.667
1,547
1,612
1,536
See the data sheet of LVDS
transmitter.
See the data sheet of LVDS
transmitter.
tv
Invalid
th
thd = 512CLK (fixed)
tc
NL204153BM21-01/01A
max.
Unit
Remarks
66.0
MHz
15.38ns (typ.)
-
ns
10.77
s
96.72kHz (typ.)
Note1
700
CLK
CLK
17.9
ms
typ.=60.0Hz
1,628
H
H
ns
ns
ns
ns
ns
ns
Invalid
-
-
-
-
-
-
-
-
-
-
Invalid
20