ATESS EVA-07D-SE/PE Shenzhen ATESS Power Technology Co.,Ltd 1st Floor of Building 3 at Sector B and 3rd Floor of Building 9, Henglong single-phase AC charger Quick installation guide Industrial Park, Shuitian, Baoan District, Shenzhen T +86 755 2998 8492 F +86 755 2998 5623...
II. Packaging list ·································································· All rights reserved. III. Installation and wiring ······················································· ATESS has the final right to interpret this user manual. The information in this manual is subject to change without notice. IV. Parameter setting ···························································· V. Operation instruction and LCD description ·····························...
Product description Packaging list Name Remark Charger User manual Quality certificate Cable hook For cabled version User card M5*12 stainless 4 Fixed the bottom bracket steels hex-head 4-10 6 of 10 Pugs for cabled version, self-drilling screws cable hook fixing M8*80 Plastic For the bottom bracket expansion plugs...
III. Installation and wiring 3.1.3 Fix the chargepoint onto the holes with expansion bolts. The input cables shall go into the pole from the bottom middle area and come out of it from the area below the cable hooker. 3.1 Installation on the ground 3.1.1 Open the packaging, you’ll see a charge point, a user manual, a pedestal and a bag of mounting accessories.
2. Click Change adapter settings. 3. Right-click on Local Area Connection and click on Properties. The position of PE terminal Parameter setting After the installation and wiring is done, connect the Charger to a computer and configure parameters via the web browser of the computer, then the Charger can be ready for use. 4.
Page 6
5. Select "Use the following IP address" and enter the IP address, Subnet Mask, Default Gateway. Click OK and close the Local Area Connection properties window. Overview of Parameter setting page 4.2 Configure parameters Connect the charger to a computer via a network cable. Open the web browser and type in http://192.168.1.5:8080/ in the address field and click enter, then enter the password: 12345678 and click enter again,the parameter setting page of the charger will open up.
Page 7
(2) Charger ID, this is the unique identification of the Charger. If the charger is to be connected to ATESS back-office server, this ID must be set as the serial number on the nameplate of the Charger. Otherwise the Charger cannot be registered on the server.
Page 8
(9) PIN of the charger, used to verify the PIN of user card. To use a RFID card with the (15) Set the max output of the charger. charger, their PIN must be consistent. If the user card has a different PIN, then it cannot be used on this charger.
Page 9
(23) Over temperature protection value, not suggested to change. (31) This is for communication testing, no need to reset. Fig.20 Fig.25 (24) Charging-allowed time. Charging can only start within this time period. This is used for off-peak charging setting. (33) DC residual current real-time detection value. If you want to charge out of this period, just press the forced on/off button at the side of the charger.
A or B.Reference part 5.2 interface introduction. If you are using the ATESS APP, Charging can be started/stopped by pressing the ON/OFF button on the APP. Plug & Charge mode operation process flow...
5.2 LCD interface introduction Interface of debug Hold down buttons A and B for 5s to enter Interface of stand by status. the debug interface and display the serial number Charging mode is displayed in the lower right etc. corner of the screen. Firmware update Interface of user card information Displayed for user to check card ID and balance...
Page 12
3. Open the txt file, write “state=1” in it and save the file. 4. Turn off the charger and insert the SD card into the charger, the update will start automatically. The indicator will first flash red and then flash green with a long beep as the end of the update(sometimes the beep sound may not be clearly heard).
VII. Troubleshooting 3. Click the “browse” button and select the firmware file. Click “Upload”, then update will start automatically. 7.1 Troubleshoot by LED behavior or LCD display If fault occurs, users can check the fault information on the LCD or by the number of blinks of the LED indicator light.
Page 14
7.2 Firmware update fails b. Please check and input the correct WiFi SSID and password to retry; 7.2.1 Firmware update failure with SD card: a. Check if the capacity is over 4G bytes,please use a SD card of less than 4GB to retry; b.
Page 15
e. Check if the charger is still connected to the computer. Please unplug it from computer otherwise the charger won’t connect to the back-office server. f. Check if server address is correct in the“Server URL” field. The correct setting is : ws://ess-charge.atesspower.com:80/ocpp/ws 1.
Page 16
(3). Right-click on Local Area Connection and click on Properties. c. Check what web browser is being used, it’s suggested to use Firefox or IE, Chrome cannot be used to update firmware. d. Check if you have input the complete content, which is http://192.168.1.5:8080, in the address field, do not leave out the http:// or the“:8080”.
VIII. Intelligent power modulation 7.5 Charging issue If charging cannot start after the car is plugged in, Introduction The charge point can monitor the total power consumption of the household during a. Check if the red emergency stop button is pressed. charging.
Specification Model EVA-07D-SE/PE (4) Set the maximum power import value in the field of External Maxlimit 420*270*1639(L*W*H) Dimension(mm) Power(kW). To avoid nuisance tripping of the main breaker, it is suggested to set Weight(kg) this parameter slightly lower than the max supply power of the property. e.g. the max supply power is 15kW, you can set the max power import to 13kW or 14kW.
Annex1 When the user has an account, you can directly enter the user name and password to log in. If you forget the password, you can click the login page, forget the password button, and follow the prompts to retrieve the password through the mailbox. 10.1.
Page 20
10.2.4 Charger switching and removal When the chargepoint status is preparing, the user can use the preset charging scheme and the reserved charging function. When there are multiple chargepoint, you can switch the chargepoint by clicking on the name of the chargepoint above. Press and hold the chargepoint name to remove the When charging, the preset charging scheme, the amount of charge, the amount of chargepoint.
Page 21
reservation: When using the reservation function, set the appointment time and plan, click the charge button to enter the reservation display interface. This interface displays the time of the You can also schedule a charge start time and set whether it will take effect every day. scheduled charging, the charging rate and the preset charging schedule.
Page 22
Authorization management To manage authorized users, you can view the authorization time, account name, and delete user in the authorization management interface. Parameter settings You can set the charger parameters by parameter setting. On the parameter setting page, the user can view the charging station ID, the authorized authentication key, and the version number (not modifiable);...
Page 23
10.2.8 Charging record Press “Record” to view past charge records, including changer ID, gun number, time, energy, cost and so on. 10.2.10 WiFi connection configuration charger In the main interface, click the WiFi connection symbol in the upper right corner to enter the WiFi connection page.
Page 24
Click AP mode to say that the current charging stub is set to AP mode. Only when the chargepoint is in AP mode can the mobile phone be used to connect the chargepoint. The chargepoint ID is displayed in the AP mode, and the electric pile parameters can be set.
Input AC 230V ELCB 11-1. Main circuit diagram 11.2 Contact Shenzhen ATESS Power Technology Co.,Ltd Address:1st Floor of Building 3 at Sector B and 3rd Floor of Building 9, Henglong, Industrial Park, Shuitian, Baoan District, Shenzhen, 518000, China Website:www.atesspower.com Service line:+8675529988492...