Page 1
ATESS NOVO EVA-11/22S-SE/PE 3-phase AC charger Quick installation guide Shenzhen Atess Power Technology Co.,Ltd 3rd floor, building 9, Henglong industrial park, the fourth industrial zone of Shuitian community, Baoan district, Shenzhen, China + 86 755 2998 8492 info@atesspower.com www.atesspower.com Revised date:2022-5-26...
II. Packaging list ·································································· All rights reserved. ATESS has the final right to interpret this user manual. The information III. Installation and wiring ······················································· in this manual is subject to change without notice. IV. Parameter setting ·····························································...
Product description Wiring definition in the side window 485A/B la+/la- lb+/lb- eSense L/N L1/L2/L3/N/PE 1.LOGO and status indicator 2.LCD display 3.RFID ready 4.Start or stop button 1. Terminal block for CT/meter wiring. The terminal definition is: 5.Socket outlet(plug holder for cabled version) 485A/485B is RS485 terminal for meter connection;...
III. Packaging list Installation and wiring 3.1 Mount on a wall Name Remark 3.1.1 Open the packaging, you’ll see a charge point, a mounting bracket, a user manual Charger and a bag of mounting accessories. There is also an RFID card if the charge point is RFID version.
Page 5
3.2 Mount on a pole 3.1.3 Put the charge point onto the bracket, and fix it with the 2 screws at the bottom of the charge point. The installation is done. 3.2.1 Open the packaging of the pole, take out the pole and mounting accessories. 3.2.2 The pole must be installed on a hard surface, concrete surface is recommended, it can also be mounted on a solid ground.
Parameter setting 3.2.4 Fix the mounting bracket onto the pole. 3.2.5 Position the charge point onto the bracket and secure it on the bracket with the 2 screws. After the installation and wiring is done, connect the Charger to a computer and configure parameters via the web browser of the computer, then the Charger can be ready for use.
Page 7
5. Select "Use the following IP address" and enter the IP address, Subnet Mask, 3. Right-click on Local Area Connection and click on Properties. Default Gateway. Click OK and close the Local Area Connection properties window. 4. Select Internet Protocol Version 4 (TCP/IPv4) and click on Properties. 4.2 Configure parameters Connect the charger to a computer via a network cable.
Page 8
(2) Charger ID, this is the unique identification of the Charger. If the charger is to be connected to ATESS back-office server, this ID must be set as the serial number on the nameplate of the Charger. Otherwise the Charger cannot be registered on the server.
Page 9
(6) MAC address. This is the MAC address used for LAN cable connection. If the charger is connected to ATESS back-office server via LAN cable and the router has MAC access control, then you can put this MAC in the router to allow the charger to access server Fig.10...
Page 10
(15) Set the max output of the charger. (23) Over temperature protection value, not suggested to change. Fig.20 Fig.15 (24) Charging-allowed time. Charging can only start within this time period. This is used for off-peak charging setting. (16) Charging mode setting. 1: APP/RFID mode; 2: RFID mode; 3: Plug&Charge mode. If you want to charge out of this period, just press the forced on/off button at the side of the charger.
(36) Press this button for the parameter change to take effect. Fig.27 APP/RFID mode operation process flow (37) This is used to upgrade firmware. If you are using the ATESS APP, Charging can be started/stopped by pressing the ON/OFF button on the APP. Fig.28...
Page 12
5.2 LCD interface introduction RFID mode: Charging can only be initiated or ceased by swiping RFID card. Interface of standby status. Charging mode is displayed at the bottom centre of the screen. Interface of user card information RFID mode operation process flow Displayed for user to check card ID and balance when swiping RFID card while EV is not connected...
Firmware update There are 2 ways to update firmware for EV charger Interface of fault status. 1. Update by SD card Displayed with fault code and fault 2. Update on parameter setting page description when fault occurs. 6.1 Update by SD card The firmware file must be named as “App.bin”.
Page 14
3. Open the txt file, write “state=1” in it and save the file. 4. Insert the SD card into the charger, turn off and back on the charger, the update will start automatically. The indicator will first flash red and then flash green with a long beep as the end of the update(sometimes the beep sound may not be clearly heard).
VII. 3. Click the ”Browse” button and select the firmware file. Click “Upload”, then update will Troubleshooting start automatically. 7.1 Troubleshoot by LED behavior or LCD display If fault occurs, users can check the fault information on the LCD or by the number of During the update, the LED indicator will behave as below, blinks of the LED indicator light.
Page 16
b. Please check and input the correct WiFi SSID and password to retry; 7.2 Firmware update fails 7.2.1 Firmware update failure with SD card: a. Check if the capacity is over 4G bytes,please use a SD card of less than 4G to retry; b.
Page 17
e. Check if the charger is still connected to the computer. Please unplug it from computer otherwise the charger won’t connect to the back-office server. f. Check if server address is correct in the“Server URL” field. The correct setting is : ws://ess-charge.atesspower.com:80/ocpp/ws d.
Page 18
(3). Right-click on Local Area Connection and click on Properties. c. Check what web browser is being used, it’s suggested to use Firefox or IE, Chrome cannot be used to update firmware. d. Check if you have input the complete content, which is http://192.168.1.5:8080, in the address field, do not leave out the http:// or the“:8080”.
VIII. Use excess solar power to charge your car 7.5 Charging issue If charging cannot start after the car is plugged in, The charge point can work with grid-tied solar system, to detect and use the residual solar a. Check if the red emergency stop button is pressed. power to charge your car that otherwise would be fed back to grid.
Page 20
8.4 Parameter configuration for this function (1) Connect the charge point to a laptop with a network cable, access the parameter setting page on the web browser of the laptop. (2) Scroll down to find the following parameters: Solar Mode, FAST, ECO or ECO+. Black White White...
Intelligent power modulation 9.2 If a meter is used, the wiring will be as the following Introduction The charge point can monitor the total power consumption of the household during charging. If the power consumption approaches the preset max value, the charge point will reduce charge power to avoid the situation of main breaker trip due to overload.
Specification (3) Select power sampling device in the field of the parameter: External Power Sampling Wiring(0: Inner CT 1: PowerMeter). 0 means CT while 1 stands for meter. NOVO EVA-11/22S-SE/PE Model 240/380/164mm Dimension(mm) <12.5 Weight(kg) Display Stainless steel& Engineering plastics& Tacrylic Casing Material Input (4) Set the maximum power import value in the field of External Maxlimit Power(kW).
Annex 11.1 Electrical diagram Fig11-1. Main circuit diagram 11.2 Contact Company Name:Shenzhen Atess Power Technology Co.,Ltd Address: 3rd floor, building 9, Henglong industrial park, the fourth industrial zone of Shuitian community, Baoan district, Shenzhen, China Website: www.atesspower.com Service line: +8675529988492...
Need help?
Do you have a question about the NOVO EVA-11-SE and is the answer not in the manual?
Questions and answers