Dormakaba GSR-EMR XEA BG Mounting Instructions
Hide thumbs Also See for GSR-EMR XEA BG:

Advertisement

Quick Links

dormakaba Deutschland GmbH
DORMA Platz 1
D‑58256 Ennepetal
DIN EN 14637:2008‑01
dormakaba Deutschland GmbH
DORMA Platz 1
D‑58256 Ennepetal
0432‑CPR‑00026‑60 EN 1155: 1997/A1: 2002/AC:2006 3 8 3‑5 1 1 4
DOP_0146
dormakaba Deutschland GmbH
DORMA Platz 1
D‑58256 Ennepetal
0432‑CPR‑00026‑83 EN 1158: 1997/A1: 2002/AC:2006 3 8 3‑7 1 1 4
DOP_0145
Contents
1
About this manual
1.1
Information about the manual
1.2
Target groups
1.3
Provided documents
1.4
Symbols and abbreviations used
1.4.1
Safety instructions
1.4.2
Further labeling
1.4.3
Tool symbols
1.5
Glossary
2
Safety
2.1
Intended use
2.2 Foreseeable misuse
2.3 Limitation of liability
2.4 Prerequisites for the operation of catching
devices
2.5 Requirements of the electrical installation
by the customer
3
Product description
3.1
RMZ
3.1.1
DIP switch on the RMZ
3.1.2
Clamp terminal assignment
of the RMZ
3.1.3
Display of the operating status
of the RMZ
3.2 EMF
3.3 Technical data
3.3.1
RMZ
3.3.2
EMF
4
Installation
4.1
Prepare the mounting of the slide rail
4.2 Mount the sliding rail of the fixed leaf
4.3 Mount the base for the RMZ
GSR-EMR XEA BG
Mounting instructions
3 8 1 1 1 4
17
17
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
5
4.4 Mount the active leaf slide rail
4.5 Mount the door closer
4.6 Shorten the connecting tube
4.7 Adjust the triggering roller on the door leaf
4.8 Mount the connecting tube
4.9 Set the sequential locking control
4.10 Check the sequential locking control
4.11 Mount the RMZ
4.12 Lay the EMF connection cable
4.13 Establish electrical connections
5
Start up
5.1
Set the DIP switch
5.2 Laying the lines
5.3 Set the fixture point
5.4 Set the release force
5.5 Mount the paneling.
5.6 Check the EMF
5.6.1
Release EMF manually
5.6.2
Delete EMF electronically
5.7 Check the function of the catching device
via the RMZ.
6
Closing the installation
6.1
Acceptance test
7
Operating
7.1
Open and lock door
7.2
Close door
8
Maintenance
9
Maintenance by dormkaba
10
Dismounting, recycling and disposal
WN 059399 45532 – 2018-12
EN
5
5
5
5
5
5
5
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
8
8
8
8
8
8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GSR-EMR XEA BG and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba GSR-EMR XEA BG

  • Page 1 Maintenance by dormkaba Installation Dismounting, recycling and disposal Prepare the mounting of the slide rail 4.2 Mount the sliding rail of the fixed leaf 4.3 Mount the base for the RMZ GSR-EMR XEA BG WN 059399 45532 – 2018-12 Mounting instructions...
  • Page 2: About This Manual

    The Step‑by‑step graphics acceptance test must only be carried out by skilled staff that is certified for this by dormakaba. The operation of the slide rail system may be carried out Position numbers of parts by any person who is mentally and physically able.
  • Page 3: Limitation Of Liability

    / smoke protection door. Do not control any further alarm systems with the fire detector of the catching device, e.g. transmission device for fire alarms. GSR-EMR XEA BG WN 059399 45532 2018-12...
  • Page 4: Installation

    IP 30 Insert the end caps connector into the slide rail. Protection category: 2. Tighten the slide rail. Smoke switch: 24 V DC/50 mA Temperature: ‑20 °C/+40 °C Rel. Humidity: max. 93 % without condensation GSR-EMR XEA BG WN 059399 45532 2018-12...
  • Page 5 Pay attention to the torque 5 Nm. The active leaf must be set in each position. 6. Remove the screw. 5. Let the fixed leaf close. The active leaf must only close automatically when the fixed leaf is closed. GSR-EMR XEA BG WN 059399 45532 2018-12...
  • Page 6 Connect optional cover smoke detectors and/or manual release buttons Connect the cover smoke detector and/or manual release buttons to the RMZ according to the enclosed connection diagrams. 2. Follow the terminating resistors (43 kOhm)! GSR-EMR XEA BG WN 059399 45532 2018-12...
  • Page 7: Closing The Installation

    The acceptance test must only be carried out by 2. Pull on the locked door leaves. skilled staff that is certified for this by dormakaba. ‣ The door leaves are released and close. The...
  • Page 8: Close Door

    For more information on this topic and many others 8 Maintenance on the dormakaba service, please go to our homepage at The performance of the maintenance must only be www.dormakaba.com. carried out by skilled personnel that is authorized by dormakaba.

This manual is also suitable for:

Ts 98 xeaGsr-emr xeaRmz xea