WFCO WF-68100-AD Series Manual

Deckmount converter-charger

Advertisement

Quick Links

OPERATOR'S MANUAL
WF-68100-AD SERIES
DECKMOUNT CONVERTER-CHARGER
ARTERRA DISTRIBUTION
WARRANTY
(877) 294-8997
warranty@wfcoelectronics.com
wfcoelectronics.com
Fax (574) 294-8698
Distributed by Arterra in the U.S.A. and Canada

Advertisement

Table of Contents
loading

Summary of Contents for WFCO WF-68100-AD Series

  • Page 1 OPERATOR’S MANUAL WF-68100-AD SERIES DECKMOUNT CONVERTER-CHARGER ARTERRA DISTRIBUTION WARRANTY (877) 294-8997 warranty@wfcoelectronics.com wfcoelectronics.com Fax (574) 294-8698 Distributed by Arterra in the U.S.A. and Canada...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY INFORMATION ...................... 3 GENERAL INFORMATION Reverse Battery Protection ....................3 Automatic Cooling Fan ....................4 Over-Temperature Protection ..................4 Electronic Current Limiting ....................4 Short Circuit Protection ....................4 CIRCUIT PROTECTION DC Fuses ..........................5 OPERATIONAL FEATURES Auto Detect ........................
  • Page 3: General Information

    WF-68100-AD Series Converter-Charger Safety Features REVERSE BATTERY PROTECTION The WF-68100-AD Series Converter-Chargers will charge the 12-volt house battery if installed. A battery does not have to be installed for WF-68100-AD Series Converter-Charger’s operation. When a battery is installed, three reverse polarity fuses are installed to protect the converter circuitry. The fuses are located on the rear panel of the enclosure near the AC power cord (Refer to Figure 1 on the following page).
  • Page 4: Automatic Cooling Fan

    If this occurs, the unit will recover once loads are reduced. SHORT-CIRCUIT PROTECTION Should a short circuit occur in the RV, the WF-68100-AD Series Converter-Charger will drop the voltage output to zero volts. If the short-circuit condition is removed and no other fault conditions are detected, the converter will resume normal operation.
  • Page 5: Operational Features

    “detected” and is then automatically set for the type of battery being used. For standard Lead Acid and AGM batteries, WFCO power converters still use the Three-Stage Smart Charging to effectively maximize battery life by monitoring through the different phases of the charge cycle.
  • Page 6: Two Stage Smart Charging

    FLOAT MODE The third mode of charging is what is called the “float” charge. This mode is designed to provide a “trickle charge” to the battery after the system observes no significant variations in current draw over a long period of time. When in “float” mode, the voltage will reduce from 13.6V to 13.2V and supply the “trickle charge”...
  • Page 7: Troubleshooting Instructions

    BULK MODE This mode is designed with two purposes in mind. First, to quickly restore the energy back into the battery. Second, to ensure the lithium cells inside the battery remain balanced. This is accomplished by boosting the output voltage to 14.6 VDC and allowing the maximum current to flow as required by the loads.
  • Page 8: General Compliance Information Agency Listings

    Figure 5 GENERAL COMPLIANCE INFORMATION Agency Listings The WF-68100-AD Series Converter-Chargers are UL-Listed, and cUL-Listed (Canadian). FCC COMPLIANCE CLASS B NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 9: Installation Instructions

    The front of the enclosure should not be obstructed to allow free air flow for the cooling fan (Figure 6). An 8AWG copper conductor shall be used to bond the WF-68100-AD Series Converter-Charger to the vehicle frame.
  • Page 10: Ac Connections

    AC CONNECTIONS The WF-68100-AD Series Converter-Chargers receive power from the power cord located to the left of the rear panel fan. Due to the higher current required from the AC line to produce the high DC current output, a 20 Amp power plug is provided.
  • Page 11 Figure 9...
  • Page 12 Arterra Distribution / WFCO. CONSUMER WARRANTY CLAIM PROCEDURE Upon determination and validation by an authorized OEM dealer that a WFCO product has a defect, a Return Goods Authorization (RGA) number will be required before the product can be returned.
  • Page 13 WARRANTY ASSISTANCE The consumer may contact the selling Dealer or OEM for warranty assistance. The consumer may also contact Arterra Distribution, exclusive distributor to WFCO Products at: (574) 294-8997 or Fax (574) 294-8698.
  • Page 14 ARTERRA DISTRIBUTION WARRANTY (877) 294-8997 warranty@wfcoelectronics.com wfcoelectronics.com Fax (574) 294-8698 Distributed by Arterra in the U.S.A. and Canada Power PROs Technical Support (877) 294-8997...

Table of Contents