Daisy-Chain Addressing; Connection Instructions - Fluke FTAP-SX50-2X8 Hardware Manual

8-port dual output fiber tap
Table of Contents

Advertisement

Daisy-Chain Addressing

CONNECTION INSTRUCTIONS

Two typical daisy-chain addressing installations are described.
INDIVIDUAL SWITCH ADDRESSING
1. For a single network appliance or PC installation, use a DRL460-6-6 control Y-cable to connect
the DB9 male lead (labeled A) to the COM 1 port of the network appliance or PC as shown
in Figure 14. For single network appliance installations, the DB9 male lead (labeled B) has
been factory tie-wrapped into a two-inch coil — approximately eight inches from the tap
connector — so it can be easily stored behind the Fluke Networks switch.
Figure 14. Connectivity diagram for individual daisy-chain addressing
2. Connect the miniature 4-pin male quick lock power supply connector into the POWER port
of the Fiber Tap, and plug the power supply into the external power source wall receptacle.
The model number and switch status will scroll on the display.
3. Set the address of each individual switch using the SET SWITCH ADDRESS function as described
in the control pull-down menu section of the Fluke Networks MANAgents software guide.
14
B
DRL460-6-6 Control Y-Cable
Server or PC
A