Power Levels - Fluke FTAP-SX50-2X8 Hardware Manual

8-port dual output fiber tap
Table of Contents

Advertisement

Specifications

POWER LEVELS

IMPORTANT
Before installing the FTAP-x-2X8 Fiber Tap, you must measure the network's power level at the point where
the Fiber Tap will be inserted. In order to minimize the bit error rate of the analysis system, the input power
to the Fiber Tap from both the transmit and receive side of each segment must be within the power level
ranges recommended in table below. By optimizing the performance of the analyzer path, the analyzer will
be able to perform as it was designed to detect and resolve network errors.
FIBER TAP MODEL
OPTICAL LEVEL
FTAP-SX50-2X8
FTAP-SX62-2X8
FTAP-LX-2X8
gigabit 5kM parts
NOTE
Dynamic Range dBm measurements include 4dB shift for spitter and connectors, also 1dB shift for output
power for connectors on top row
LX = Longwave, 1270 to 1355 nm, single-mode
SX = Shortwave, 770 to 860 nm, multi-mode
BIT RATE
gigabit
1,250Mbps
gigabit
1,250Mbps
1,250Mbps
DYNAMIC RANGE dBm, 1X10
INPUT
INPUT
CHANNEL 1–8
DAISY
+4 to -13
0 to -16
+4 to -13
0 to -16
+1 to -15
-3 to -18
-12
BER
OUTPUT
TAP
-4 to -11
-4 to -11
-3 to -12.5