LEGRAND Wattstopper DT-305 Manual

360 dual technology • low voltage occupancy sensor (version 3) with manual on feature
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

No: 23948 – 07/18 rev. 5
Catalog Number • Numéro de Catalogue • Número de Catálogo: DT-305
Country of Origin: Made in China • Pays d'origine: Fabriqué en Chine • País de origen: Hecho en China
DT-305 -U is BAA and TAA compliant (Product produced in the U.S.)
UNIT DESCRIPTION
The Wattstopper DT-305 360° Dual Technology occupancy
sensors combine advanced passive infrared (PIR) and ultrasonic
technologies into one unit. The combination of these technologies
helps to eliminate false triggering problems even in difficult
applications.
The DT-305 turns lighting systems on and off based on
occupancy. The DT-305 provides numerous operating modes that
can be combined to create the ideal custom control. The sensors
can be configured to turn lighting on, and hold it on as long as
either or both technologies detect occupancy. After no movement
is detected for a user specified time (30 seconds to 30 minutes)
the lights are switched off. A "walk-through" mode can turn lights
off after only 3 minutes, if no activity is detected after 30 seconds
of an occupancy detection.
The DT-305 operates on 24V, supplied by Wattstopper Power
Packs.
The DT-305 provides a 360° coverage pattern. The coverage shown represents walking motion at a mounting height of 8-12 feet. For
building spaces with lower levels of activity or with obstacles and barriers, coverage size may decrease. The coverage for PIR ONLY
trigger mode varies with mount height. Refer to pattern below for details. Ultrasonic coverage is roughly the same for 8-12 foot mount
heights. Refer to PIR and Ultrasonic trigger mode coverage for details.
Drawings not to scale, representative of PIR and
Ultrasonic Trigger Mode major motion coverage.
0
8' (2.4m)
10' (3m)
12' (3.7m)
40'
30'
20'
(12.2m)
(9.1m)
(6.1m)
PIR Only Coverage
COVERAGE PATTERN
Side View
10'
0
10'
20'
(3m)
(3m)
(6.1m)
Wattstopper
360° Dual Technology • Low Voltage Occupancy Sensor (version 3)
with Manual On feature
Double technologie à 360° • Détecteur de présence basse tension (v3)
avec les fonctionnalité de marche manuelle
Doble tecnología de 360° • Sensor de presencia de bajo voltaj (v3)
con función de encendido manual
Installation Instructions • Instructions d'Installation • Instrucciones de Instalación
Voltage ...................................................... 18–28VDC/VAC half rectified
Current Consumption @24VDC/VAC ..................16mA (DC), 69mA (AC)
Power Supply ..................................................Wattstopper Power Packs
Isolated Relay Rating ...................................................1A @30VDC/VAC
Operating Temperature .................................... 32° to 131°F (0° to 55°C)
Time Delay Adjustment ................................... 30 seconds to 30 minutes
Walk-Through Mode ..........................3 minutes if no activity after 30 sec
Test Mode ....................................................5 sec. upon DIP switch reset
PIR Coverage (Typical) ................................................................ 1300 ft²
Sensitivity Adjustment ....................High or Low (DIP switch setting)
Ultrasonic Coverage (Typical) ...................................................... 1300 ft²
Sensitivity Adjustment ................................ Min. to Max. (trimpot)
Frequency .......................................................................... 40kHz
UL & CUL Listed for use with Wattstopper Power Packs
PIR
Coverage
Ultrasonic
Coverage
30'
40'
(9.1m)
(12.2m)
(10.97m x 10.97m)
®
SPECIFICATIONS
Top View
36 ft x 36 ft
8-12 foot Mounting Height
36 ft
(10.97m)

Advertisement

Table of Contents
loading

Summary of Contents for LEGRAND Wattstopper DT-305

  • Page 1 DT-305 -U is BAA and TAA compliant (Product produced in the U.S.) UNIT DESCRIPTION SPECIFICATIONS The Wattstopper DT-305 360° Dual Technology occupancy Voltage ............18–28VDC/VAC half rectified sensors combine advanced passive infrared (PIR) and ultrasonic Current Consumption @24VDC/VAC ....16mA (DC), 69mA (AC) technologies into one unit.
  • Page 2: Placement Guidelines

    • Wire from one side of switch to +24V terminal on sensor. +24V Common • Wire from other side of switch to Man Switch terminal on sensor. www.legrand.us.com 800.879.8585 Wiring the ISOLATED RELAY: The Isolated Relay is rated for 1A@30VAC/VDC. Connect the wires necessary to the application that requires this output: •...
  • Page 3: Connecting Wires

    CONNECTING WIRES • Care should be taken to separate high voltage power from low voltage (Class 2) control wiring. • All connections to sensor are low voltage, Class 2. Standard wiring with two local off switches Manual-On wiring with low voltage momentary switch Optional Local Off White...
  • Page 4: Sensor Adjustment

    SENSOR ADJUSTMENT This unit is pre-set for basic operation as described in this guide. Adjustment is optional. The sensors are factory preset to allow for quick installation in most applications. Verification of proper wiring or coverage, or customizing the Keyhole slots Ultrasonic sensitivity trimpot (for mounting to...
  • Page 5: Dip Switch Setting

    DIP SWITCH SETTING Feature Switch# Time Delay: Switches 1, 2, 3 Time Delay 1 2 3 The sensor will hold the lights ON as long as occupancy is detected. The time delay countdown starts Test Mode/20 min when no motion is detected. After no motion is detected for the length of the time delay, the sensor will 30 seconds 5 minutes turn the lights OFF.
  • Page 6: Ordering Information

    Green LED does not flash. Ultrasonic sensitivity setting may need to be increased. Turn adjustment trimpot clockwise until the LED begins to flash when movement occurs. Green LED is on steady. Check ultrasonic sensitivity trimpot. Fully counterclockwise position is the override for the sensor. Turn trimpot clockwise until LED flashes only when movement occurs in the desired coverage area.
  • Page 7: Description De L'appareil

    INSTRUCTIONS EN FRANÇAIS DESCRIPTION DE L’APPAREIL CARACTÉRISTIQUES Les détecteurs de présence à double technologie 360° Tension ....18–28 VCC/VCA courant alternatif redressé mono alternance DT-305 de Wattstopper associent les technologies Consommation de courant @24VCC/VCA ......16mA (CC), 69mA (CA) avancées de l’infrarouge passif (IRP) et des ultrasons Alimentation électrique ........
  • Page 8: Instructions De Câblage

    Patent Pending +24V de la marche manuelle avec un interrupteur instantané basse tension ») – Common www.legrand.us.com raccordez : 800.879.8585 • Fil d’un côté de l’interrupteur à la borne + 24 V du détecteur. • Fil de l’autre côté de l’interrupteur à la borne Interrupteur man. du détecteur.
  • Page 9: Montage Du Détecteur

    RACCORDEMENT DES FILS • Vous devez faire attention à séparer les fils haute tension du secteur des fils de régulation basse tension (classe 2). • Tous les raccordements au détecteur sont basse tension, classe 2. Câblage standard avec deux interrupteurs d’arrêt local Câblage de la marche manuelle avec un interrupteur momentané...
  • Page 10: Réglage Du Détecteur

    RÉGLAGE DU DÉTECTEUR L’unité est préréglée pour un fonctionnement de base, comme décrit dans ce guide. LE RÉGLAGE EST OPTIONNEL. Les détecteurs sont préréglés en usine afin de vous permettre de l’installer rapidement dans la plupart des applications. Pour vérifier que le Potentiomètre d’ajustement Fentes en trou de serrure de la sensibilité...
  • Page 11: Protection Contre La Surcharge

    RÉGLAGE DE L’INTERRUPTEUR DIP Paramètre N° d’interrupteur Temporisation : Interrupteurs 1, 2, 3 Temporisation 1 2 3 Mode test/20 min Le détecteur maintient les lumières ALLUMÉES tant qu’une présence est détectée. Le compte à 30 secondes rebours de temporisation démarre lorsqu’aucun mouvement n’est détecté. En l’absence de mouvement 5 minutes pendant toute la durée de la temporisation, le détecteur ÉTEINT les lumières.
  • Page 12: Entretien

    La DEL verte ne clignote pas Il peut être nécessaire d’augmenter le réglage de la sensibilité ultrasonique. Tournez le potentiomètre d’ajustement dans le sens horaire jusqu’à ce que la DEL commence à clignoter en cas de mouvements. La DEL verte est constamment allumée Vérifiez le potentiomètre d’ajustement de la sensibilité...
  • Page 13: Especificaciones

    INSTRUCCIONES EN ESPAÑOL DESCRIPCIÓN DE LA UNIDAD ESPECIFICACIONES Los sensores de presencia con doble tecnología Voltaje ............18–28 VCC/VCA rectificada de media onda de 360° DT-305 Wattstopper combinan tecnologías Consumo de corriente @24VCC/VCA ......... 16mA (CC), 69mA (CA) infrarrojas pasivas (PIR) con tecnologías Suministro de energía ..........Paquetes de alimentación Wattstopper ultrasónicas avanzadas en una unidad.
  • Page 14: Instrucciones De Cableado

    Man. Switch Patent Pending sensor. +24V Common www.legrand.us.com Para agregar un INTERRUPTOR MANUAL como el interruptor de palanca 800.879.8585 momentáneo LVSW o el interruptor momentáneo de bajo voltaje RS2-3 para las aplicaciones anteriores (consulte el diagrama de cableado “Cableado de encendido manual con interruptor momentáneo de bajo voltaje”), conecte:...
  • Page 15: Cables De Conexión

    CABLES DE CONEXIÓN • Se debe tener cuidado para separar la energía de alto voltaje del cableado de control de bajo voltaje (Clase 2). • Todas las conexiones que van al sensor son de bajo voltaje, Clase 2. Cableado estándar con dos interruptors de apagado local Cableado de Encendido manual con interruptor momentáneo de bajo voltaje Interruptor...
  • Page 16: Ajuste Del Sensor

    AJUSTE DEL SENSOR Esta unidad se preconfigura en fábrica para el funcionamiento básico como se describe en esta guía. El ajuste es opcional. Los sensores vienen con ajuste predeterminado de fábrica para permitir una instalación rápida en la mayoría de las aplicaciones. Ranuras de orificios tipo Potenciómetro de bocallave (para montaje...
  • Page 17: Configuración Del Interruptor Dip

    CONFIGURACIÓN DEL INTERRUPTOR DIP Función Interruptor n.° Tiempo de demora: Interruptores 1, 2, 3 1 2 3 Tiempo de retardo El sensor mantendrá las luces ENCENDIDAS siempre y cuando se detecte una presencia. La Modo de prueba/20 min. cuenta regresiva del tiempo de retardo se inicia cuando no se detecta movimiento. Si no se detecta 30 segundos movimiento durante la duración de la demora de tiempo, el sensor APAGA las luces.
  • Page 18: Información Para Pedidos

    La luz LED verde está encendida de manera constante. Verifique el potenciómetro de sensibilidad ultrasónica. La posición completamente contraria a las manecillas del reloj es la anulación del sensor. Gire el potenciómetro en el sentido de las manecillas del reloj hasta que la luz LED destelle solamente cuando se produce el movimiento en el área de cobertura deseada.
  • Page 19 No. 23948 – 07/18 rev. 5 © Copyright 2018 Legrand All Rights Reserved. 800.879.8585 © Copyright 2018 Tous droits réservés Legrand. www.legrand.us/wattstopper © Copyright 2018 Legrand Todos los derechos reservados.

Table of Contents