Installation

The reader should be installed onto a solid surface using
suitable mounting fixtures. Wiring should only be
performed while the control panel is powered off.
Step 1) Using the 1:1 mounting template supplied, mark
out the location of the 2 mounting holes and
the cable exit hole before drilling out all points
as necessary.
PR113B & PR114B Mounting Template
6 x 4.0mm
(1/8") holes
Tamper Switch
Do Not Create A Hole
In This Location
Connection Cable
Entry Point
Figure 3: Mounting Template (Not to Scale)
PR113B & PR114B Mounting Template.ai
Step 2) If the reader is to occupy an address on the
LAN other than address 1, you will need set the
required address before mounting. Note each
reader on the system must have a unique
address. See Table 2: for more information.
Step 3) Once the address has been set, terminate the
required wires referring to the "Connection Dia-
gram" on page 6. Unused wires should be
insulated to prevent short circuits.
Step 4) If using the on board lock output to open the
door, you must make sure to use a relay and
protection diode as shown.
Step 5) Once the wiring is complete, mount the reader
to the wall and fit the cover plate using the M3 x
6mm hex screws.
Bosch Security Systems
12/13 PR113B-PR114BIRG FTR1.0
Scale 1:1
48.0mm
Rev 1
PR113B-PR114B

Reader Operation

LAN Readers can be configured to provide system area
control, door access control or both depending on the
installation requirements.
As there is no LCD display on the readers, feedback is
provided via the red, green and blue indicators and the
reader sounder.
The readers also include an egress input and lock output
which can be used to control door access if required.
Using the on board lock output is not recommend-
i
ed when the reader is being used on an external
Note
wall of the building. In this case it is recommended
that you run the lock control wires directly to an
output located on the main panel or output ex-
pander module located inside the building.
LED Indicators
The Red and Green indicators on the reader show area
status while the Blue indicator shows door status. The
addition of the Blue indicator allows the system to
display both area and door status at the same time if
required.
LED Operation For Area Control
Led
Condition
On
Red
Flashing
On
Green
Flashing
Red &
Both On
Green
Red On
Red &
and Green
Green
Flashing
Red &
Alternate
Green
Flashing
Red &
Both Off
Green
Table 3: Reader LED's - Area Control
The LED indicators will only display the status of
i
the programmed home area. You cannot move
Note
between areas from this reader. If you require mul-
tiple area status visibility you should use a display
keypad like the CP700B.
Installer Reference Guide
Meaning
Area All On
Area Alarm
Area is OFF
Area not ready to turn on -
zone(s) unsealed
Area armed in Part mode
and all zones sealed.
Area armed in Part mode
with zones unsealed.
Keypad initialising during
power up or LAN scan.
Home Area and Access
Group not programmed or
keypad not powered.
3