HP ProCurve 5406zl-48G Intelligent Edge Datasheet page 6

Procurve 5406zl series; procurve 3500yl series
Hide thumbs Also See for ProCurve 5406zl-48G Intelligent Edge:
Table of Contents

Advertisement

HP ProCurve Switch 5400zl/3500yl Series
Operating temperature
Operating relative humidity
Non-operating/Storage temperature
Non-operating/Storage relative humidity
Altitude
Acoustic
Electrical characteristics
Description
Maximum heat dissipation
Voltage
Current
Power consumption
Frequency
Notes
Safety
Emissions
Immunity
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F
(40°C) when used with any X2 10-GbE
15% to 95% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 90% @ 149ºF (65ºC), non-condensing
up to 15000 ft. (4.6 km)
Power: 52.7 dB, Pressure: 44.8 dB ISO 7779,
ISO 9296
The switch automatically adjusts to any
voltage between 100-127 and 200-240 volts
and either 50 or 60 Hz
670 BTU/hr (706 kJ/hr), (max non-PoE); 940
BTU/hr (991 kJ/hr) (max using PoE)
100-127 / 200-240 VAC
10.0 / 5.0 A
723 W
50 / 60 Hz
Maximum power rating is the worst-case
theoretical maximum power number with fully
loaded PoE, 100% traffic, all ports plugged in,
and all modules populated.
Maximum power draw if not using any PoE
power is 200 W (1.8 A @ 110 V, 0.9 A @ 220
V). Full load switch only heat spec listed
above subtracts heat dissipated in external
PoE powered devices. Heat dissipation does
not include heat dissipated by the PoE
powered devices themselves.
CSA 22.2 No. 60950; UL 60950; IEC 60950;
EN 60950
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period;
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
32ºF to 131ºF (0ºC to 55ºC); 32°F to 104°F
(40°C) when used with any X2 10-GbE
15% to 95% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 95% @ 149ºF (65ºC), non-condensing
up to 15000 ft. (4.6 km)
Power: 55.1 dB, Pressure: 45.3 dB ISO 7779,
ISO 9296
The switch automatically adjusts to any
voltage between 100-127 and 200-240 volts
with either 50 or 60 Hz
810 BTU/hr (854 kJ/hr), (max non-PoE);
1,090 BTU/hr (1149 kJ/hr) (max using PoE)
100-127 / 200-240 VAC
10.0 / 5.0 A
759 W
50 / 60 Hz
Maximum power rating is the worst-case
theoretical maximum power number with fully
loaded PoE, 100% traffic, all ports plugged in,
and all modules populated.
Maximum power draw if not using any PoE
power is 200 W (1.8 A @ 110 V, 0.9 A @ 220
V). Heat dissipation does not include heat
dissipated by the PoE powered devices
themselves.
CSA 22.2 No. 60950; UL 60950; IEC 60950;
EN 60950
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period;
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
32ºF to 131ºF (0ºC to 55ºC); 0°C to 40°C with
J8705A, J8706A, or J8707A modules installed
15% to 95% @ 131ºF (55ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
15% to 95% @ 149ºF (65ºC), non-condensing
up to 10000 ft. (3 km)
Power: 57 dB, Pressure: 40.2 dB ISO 7779,
ISO 9296
Chassis ships without power supplies. Two
power-supply slots available; two different
power supplies available. See power-supply
products for additional specifications.
2450 BTU/hr (2584 kJ/hr), (max non-PoE);
3700 BTU/hr (3903 kJ/hr) (max using PoE)
100-127 / 200-240 VAC
50 / 60 Hz
Power supplies must be ordered separately.
One J8712A or J8713A can power the
J8697A chassis. Heat dissipation does not
include heat dissipated by the PoE powered
devices themselves.
CSA 22.2 No. 60950; UL 60950; IEC 60950;
EN 60950
FCC Class A; VCCI Class A; EN
55022/CISPR 22 Class A
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV
(signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period;
30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
6