Download Print this page
Pepperl+Fuchs schmersal RSS260 AS Operating Instructions Manual
Pepperl+Fuchs schmersal RSS260 AS Operating Instructions Manual

Pepperl+Fuchs schmersal RSS260 AS Operating Instructions Manual

Advertisement

Quick Links

Operating instructions
Safety sensor
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Cross Reference:
Schmersal
Schmersal
Pepperl+Fuchs
Article number
Description
Article number
103004641
RSS260-I2-ST-AS
319858
103004318
RST260-1
319859
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Actuating directions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.3 Switching distance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.4 Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.6 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .5
5
5.1 Programming the slave address . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.2 Configuration of the safety monitor . . . . . . . . . . . . . . . . . . . . . . . . .5
5.4 Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 LED indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.2 Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.3 Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.4 Diagnostic signal periphery error . . . . . . . . . . . . . . . . . . . . . . . . . . .6
6.5 Read-out of the parameter port . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
7
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
Pepperl+Fuchs
Description
VAA-1E-IEI3-READER1-S-V31
VAZ-IEI3-TAG1-S

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

1.4 Appropriate use

The Schmersal range of products is not intended for private consumers.
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
EN
EU Declaration of conformity
1. About this document
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
RSS260 AS
1

Advertisement

loading

Summary of Contents for Pepperl+Fuchs schmersal RSS260 AS

  • Page 1: Table Of Contents

    8.2 Disposal ..........7 EU Declaration of conformity Cross Reference: Schmersal Schmersal Pepperl+Fuchs Pepperl+Fuchs Article number Description Article number Description 1.
  • Page 2: General Safety Instructions

    Operating instructions Safety sensor RSS260 AS 1.5 General safety instructions 2.3 Purpose The user must observe the safety instructions in this operating instructions This non-contact, electronic safety sensor is designed for application in manual, labelled with the caution or warning symbol above, the country- safety circuits and is used for monitoring the position of movable safety specific installation standards as well as all prevailing safety regulations and guards.
  • Page 3: Safety Classification

    Operating instructions Safety sensor RSS260 AS Electrical data – AS-Interface 2.5 Safety classification AS-i supply voltage: 18.0 ... 31.6 VDC, protection Standards: EN ISO 13849-1, IEC 61508 against polarity reversal up to e AS-i power consumption: ≤ 100 mA Control Category: AS-i device insulation: internal short-circuit proof PFH:...
  • Page 4: Actuating Directions

    Operating instructions Safety sensor RSS260 AS 3.2 Actuating directions 3.4 Adjustment The continuous signal of the yellow LED signals the actuator detection; the Actuation from front flashing of the yellow LED after a delay signals that the safety sensor is actuated in the hysteresis area.
  • Page 5: Electrical Connection

    Operating instructions Safety sensor RSS260 AS 5. Functions and configuration 5.1 Programming the slave address The slave address is programmed through the M8 connector. Any address from 1 to 31 can be set by means of the AS-i bus master or a hand-held programming device.
  • Page 6: Diagnostic

    Operating instructions Safety sensor RSS260 AS 6. Diagnostic 6.1 LED indications The LED's have the following meaning (to EN 62026-2): LED green-red AS-Interface supply voltage / (AS-i Duo LED): AS-Interface communication error / Slave address = 0 / Periphery error detected / Enabling inhibit (tamper protection time) active Yellow LED: Device status (enabling status) /...
  • Page 7: Set-Up And Maintenance

    Operating instructions Safety sensor RSS260 AS 7. Set-up and maintenance 8. Disassembly and disposal 7.1 Functional testing 8.1 Disassembly The safety function of the safety components must be tested. The The safety switchgear must be disassembled in a de-energised following conditions must be previously checked and met: condition only.

This manual is also suitable for:

Schmersal rst260-1Vaa-1e-iei3-reader1-s-v31Vaz-iei3-tag1-s103004641103004318319858 ... Show all