Download Print this page

Chromalox CAF-6 Installation, Operation And Maintenance Manual

Draft barrier heaters

Advertisement

Quick Links

CAF-6
TABLE 1 — Specifications
Model
CAF-6F205
CCAS-8F205
CAF-6F205
CCAS-8F205
CAF-6F205
CCAS-8F205
CAF-6F205
CCAS-8F205
CAF-6F307
CCAS-8F307
CAF-6F307
CCAS-8F307
CAF-6F307
CCAS-8F307
CAF-6F307
CCAS-8F307
CAF-6F410
CCAS-8F410
CAF-6F410
CCAS-8F410
CAF-6F410
CCAS-8F410
CAF-6F410
CCAS-8F410
CAF-6F512
CCAS-8F512
CAF-6F512
CCAS-8F512
CAF-6F512
CCAS-8F512
CAF-6F512
CCAS-8F512
CAF-6F615
CCAS-8F615
CAF-6F615
CCAS-8F615
CAF-6F615
CCAS-8F615
CAF-6F615
CCAS-8F615
CAF-6F717
CCAS-8F717
CAF-6F717
CCAS-8F717
CAF-6F717
CCAS-8F717
CAF-6F820
CCAS-8F820
CAF-6F820
CCAS-8F820
CAF-6F820
CCAS-8F820
CAF-6F922
CCAS-8F922
CAF-6F922
CCAS-8F922
CAF-6F922
CCAS-8F922
CAF-6F025
CCAS-8F025
CAF-6F025
CCAS-8F025
CAF-6F025
CCAS-8F025
© 2010 Chromalox, Inc.
Draft Barrier Heaters
Type CAF-6 and CCAS-8
Model
Volts
Phase
120
1
208
1
240
1
277
1
120
1
208
1
240
1
277
1
120
1
208
1
240
1
277
1
120
1
208
1
240
1
277
1
120
1
208
1
240
1
277
1
208
1
240
1
277
1
208
1
240
1
277
1
208
1
240
1
277
1
208
1
240
1
277
1
CCAS-8
Watts
Amps
BTUH
500
4.2
1,706
500
2.4
1,706
500
2.1
1,706
500
1.8
1,706
750
6.3
2,559
750
3.6
2,559
750
3.1
2,559
750
2.7
2,559
1000
8.3
3,412
1000
4.8
3,412
1000
4.2
3,412
1000
3.6
3,412
1250
10.4
4,265
1250
6
4,265
1250
5.2
4,265
1250
4.5
4,265
1500
12.5
5,118
1500
7.2
5,118
1500
6.3
5,118
1500
5.4
5,118
1750
8.4
5,971
1750
7.3
5,971
1750
6.3
5,971
2000
9.6
6,824
2000
8.3
6,824
2000
7.2
6,824
2250
10.8
7,677
2250
9.4
7,677
2250
8.1
7,677
2500
12
8,530
2500
10.4
8,530
2500
9
8,530
(Supersedes PF492)
JULY, 2002
Dimensions (In.)
Height
Length
Depth
6/7.5
24.3
6/7.5
24.3
6/7.5
24.3
6/7.5
24.3
6/7.5
36.3
6/7.5
36.3
6/7.5
36.3
6/7.5
36.3
6/7.5
48.3
6/7.5
48.3
6/7.5
48.3
6/7.5
48.3
6/7.5
60.3
6/7.5
60.3
6/7.5
60.3
6/7.5
60.3
6/7.5
72.3
6/7.5
72.3
6/7.5
72.3
6/7.5
72.3
6/7.5
84.3
6/7.5
84.3
6/7.5
84.3
6/7.5
96.3
6/7.5
96.3
6/7.5
96.3
6/7.5
108.3
6/7.5
108.3
6/7.5
108.3
6/7.5
120.3
6/7.5
120.3
6/7.5
120.3
PF492-1
Weight (Lbs.)
2.5
7
2.5
7
2.5
7
2.5
7
2.5
9.5
2.5
9.5
2.5
9.5
2.5
9.5
2.5
12
2.5
12
2.5
12
2.5
12
2.5
15
2.5
15
2.5
15
2.5
15
2.5
18
2.5
18
2.5
18
2.5
18
2.5
21.5
2.5
21.5
2.5
21.5
2.5
25
2.5
25
2.5
25
2.5
29
2.5
29
2.5
29
2.5
33
2.5
33
2.5
33

Advertisement

loading

Summary of Contents for Chromalox CAF-6

  • Page 1 CAF-6F820 CCAS-8F820 CAF-6F922 CCAS-8F922 CAF-6F922 CCAS-8F922 CAF-6F922 CCAS-8F922 CAF-6F025 CCAS-8F025 CAF-6F025 CCAS-8F025 CAF-6F025 CCAS-8F025 © 2010 Chromalox, Inc. Draft Barrier Heaters Type CAF-6 and CCAS-8 CCAS-8 Volts Phase Watts Amps 1000 1000 1000 1000 1250 10.4 1250 1250 1250 1500 12.5...
  • Page 2: Model Number Description

    TABLE 2 CAF-6 CCAS-8 Code 11 = 120/1 21 = 208/1 31 = 240/1 41 = 277/1 Code Wattage (See Table) Code Length 2 = 2 ft. 3 = 3 ft. 4 = 4 ft. 5 = 5 ft. 6 = 6 ft. 7 = 7 ft. 8 = 8 ft. 9 = 9 ft. 10 = 10 ft.
  • Page 3 Draft Barrier Heater Installation (Wall) 1. Once the correct mounting height is established, scribe or snap a level line on the wall to maintain each heater back plate in horizontal alignment, when mounting. 2. Remove heater front cover by lifting top rear edge to unsnap cover from back plate (store cover in safe location to avoid damage to the finish).
  • Page 4: Wiring Diagrams

    2. Run a ground jumper from the ground screw in one terminal box to the ground screw in the adjacent terminal box. (See Figure 4.) Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. WIRING Table 4: Terminal Box Volumes (Cubic Inches)

This manual is also suitable for:

Ccas-8