ADEMCO VISTA 20HWSE Programming Form page 7

2-partitioned security system

Advertisement

OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR
80 OUTPUT DEVICES –
*
the programming procedure in the installation manual as you enter the data during the displays and prompts that appear
in sequence.
Notes: 1. For Relays, field
2. For Powerline Carrier devices, field
3. Tampers of expansion units cannot be used to operate devices.
DEVICE
NUMBER
OUTPUT RELAY
01
OR P.L.C.D.*
OUTPUT RELAY
Ê02
OR P.L.C.D.*
OUTPUT RELAY
Ê03
OR P.L.C.D.* Ê
OUTPUT RELAY
ÊÊ04
OR P.L.C.D.*
ÊÊÊÊÊÊÊÊ05
P.L.C.D.*
ÊÊÊÊÊÊÊÊ06
P.L.C.D.*
ÊÊÊÊÊÊÊÊ07
P.L.C.D.*
ÊÊÊÊÊ ÊÊ08
P.L.C.D.*
+
*
P.L.C.D. = Powerline Carrier Device (X-10).
Where:
X-10 SELECT = Powerline Carrier Device Enter "1" if Powerline Carrier Device is being used, enter "0" if relay is being used.
A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
Ê
EV
= EVENT
Z L = ZONE LIST 1, 2, or 3 (from Field
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
Choices for System Operation are:
*** Or at Disarming, whichever occurs earlier.
P = PARTITION No.ÊÊ1, 2, or 0 for Any
www.PDF-Zoo.com
Applicable only if Relays and/or Powerline Carrier Devicess are to be used.
This is an interactive menu mode. Fill in the required data on the worksheet on below and follow
25 must be programmed for a 4229 (Relays 01 and 02), OR for a 4204 (Relays 01 to 04).
*
S T A R T
=
either or both
ZONE
ACTION
EVENT
LIST
(A)
(EV)
(ZL)
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.
"STOP" RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action will STOP. It
NOTE: Do not use input type "BR" transmitters in a zone list to STOP a relay action, since these
transmitters do not send restores.
00 = Not Used
01 = Entry/Exit#1
02 = Entry/Exit#2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Burglary Alarm
36 = **At Bell Timeout***
** Use 0 (Any) for Partition No. (P) entry.
firealarmresources.com
27 must be programmed with a House Code.
*
-
ÊÊÊÊÊÊÊÊÊÊÊÊ
ZONE TYPEÊÊPART'N
RESTORE of
SYST OP'N
No.
ÊÊÊÊÊ(ZT)
(P)
*
81) or 0 = Not Used.
need not be same list as used for START.
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire Trouble
10 = Interior w/Delay
24= Silent Burglary
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
41 = **AC Power Failure
42 = **System Battery Low
43 = Communication Failure
– 7 –
80, and
*
S T O P
=
-
either or both
ZONE TYPEÊÊÊÊPART'N
ZONE LIST
/SYST OP'N
(ZL)
(ZT)
Note : Any zone in "ZT" going into alarm,
fault, or trouble will actuate relay.
Any zone of that type that restores
will stop relay action.
52 = Kissoff
58 = Duress
Note: In normal operation mode:
Code + # + 7 + N Key Entry starts Device N.
Code + # + 8 + N Key Entry stops Device N.