ZONE LISTS FOR OUTPUT DEVICES –
*
below and follow the procedure in the installation manual as you enter the data during the displays and prompts that
appear in sequence.
Note:
Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may
include any or all of system's zone numbers.
Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).
,
Zone List 2: Started or stopped by zone numbers (enter 00 to end entries).
,
Zone List 3: Started or stopped by zone numbers AND/OR assignment of Chime zones (enter 00 to end entries)
,
Zone List 4: Assignment of common lobby zones (enter 00 to end entries).
,

SPECIAL MESSAGES

OC = OPEN CIRCUIT (no communication between Console and Control).
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This
will revert to READY in appx. 1 minute, which allows PIRS, etc. to stabilize. To bypass this delay, press: [#] + [0].
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. Correct the programming and
then completely de-power and re-power the control to clear this indication and remove the disable indication.
TO ENTER PROGRAMMING MODE:
1. POWER UP, then depress [
OR
2. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.
OR
3. If different Installer Code is programmed, key: New Installer Code + 8 + 0 + 0.
(if
98 was used to exit previously, method 1 above must be used to enter the program mode again)
*
TO EXIT PROGRAMMING MODE:
98
Exits programming mode and prevents re-entry by: Installer Code + 8+ 0 + 0. If
*
mode, system must be powered down, and method 1 above used to enter the programming mode.
99
Exits programming mode and allows re-entry by: Installer Code + 8 + 0 + 0 or: Power-up, then press "
*
within 50 seconds of power up.
www.PDF-Zoo.com
This is an interactive mode. Fill in the required data on the worksheet
,
,
,
,
,
,
,
,
,
,
,
,
] and [#] both at once, within 50 seconds of powering up.
*
®
A L A RM DE V I CE MA NUFA CTURI NG CO .
A DIVISION OF PITTWAY CORPORATION
165 Eileen Way, Syosset, New York 11791
Copyright © 1997 PITTWAY CORPORATION
firealarmresources.com
,
,
,
,
,
,
,
,
,
,
,
,
*
,
,
...etc.
,
,
...etc.
,
,
...etc.
,
,
...etc.
98 is used to exit programming
" and "#"
*

Advertisement

loading

This manual is also suitable for:

Vista-20se