Indoor Unit Error Display - Vivax Mission Inverter Series Service Manual

Table of Contents

Advertisement

Mission Inverter

11.1 Indoor Unit Error Display

Operation lamp
Timer lamp
☆ 1 time
☆ 2 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 5 times
48
Display
X
E0
X
E1
X
E3
X
E4
X
E5
X
EC
O
F0
O
F1
O
F2
O
F3
O
F4
O
F5
P0
P1
P2
P4
O ( light )
LED STATUS
Indoor unit EEPROM parameter error
Indoor / outdoor units communication error
Indoor fan speed has been out of control
Indoor room temperature sensor T1 open circuit or short
circuit
Evaporator coil temperature sensor T2 open circuit or short
circuit
Refrigerant leakage detection
Overload current protection
Outdoor ambient temperature sensor T4 open circuit or
short circuit
Condenser coil temperature sensor T3 open circuit or short
circuit
Compressor discharge temperature sensor T5 open circuit
or short circuit
Outdoor unit EEPROM parameter error
Outdoor fan speed has been out of control
IPM malfunction or IGBT over-strong current protection
Over voltage or over low voltage protection
High temperature protection of compressor top diagnosis
and solution
Inverter compressor drive error
X ( off )
☆( flash )
DM16-01.01.22en
Service manual

Advertisement

Table of Contents
loading

Table of Contents