Vivax Mission Inverter Series Service Manual page 57

Table of Contents

Advertisement

DM16-01.01.22en
11.2.7 IPM malfunction or IGBT over-strong current protection diagnosis and solution(P0)
Error Code
Malfunction decision
conditions
Supposed causes
Trouble shooting:
I PM continuity check
Turn off the power, let the large capacity electrolytic capacitors discharge completely, and dismount the IPM. Use a digital
tester to measure the resistance between P and UVWN; UVW and N.
Digital tester
(+)Red
(-)Black
N
U
P
V
W
Service manual
P0
When the voltage signal that IPM send to compressor drive chip
is abnormal, the display LED will show "P0" and AC will turn off.
Wiring mistake
IPM malfunction
Outdoor fan ass'y faulty
Compressor malfunction
Outdoor PCB faulty
Normal resistance value
(Several MΩ)
Digital tester
(+)Red
(-)Black
U
V
N
W
(+)Red
Mission Inverter
Normal resistance value
(Several MΩ)
57