DM16-01.01.22en
11.2.5 Open circuit or short circuit of temperature sensor diagnosis and solution(E5)
Error Code
Malfunction decision
conditions
Supposed causes
Trouble shooting:
Check the connection
between temperature
sensor and PCB.
Yes
Measure the resistance
value of the sensor
Yes
Replace indoor or outdoor
main PCB
Service manual
E4/E5/F1/F2/F3
If the sampling voltage is lower than 0.06V or higher than 4.94V,
the LED will display the failure.
Wiring mistake
Sensor faulty
No
No
Correct the connection
Repalce the sensor