Chapter 4
Technical Specifications
Transmit Power Level
(Adjustable)
Size of Fast Fourier Transform
(FFT) Channels
Type of Modulation
Dynamic Range (Receiver)
Dynamic Range (Transmitter)
Section 4.3

Operating Environment

The RUGGEDCOM WIN5237-IS is rated to operate under the following environmental conditions.
Ambient Operating
a
Temperature
Ambient Storage Temperature
Ambient Relative Humidity
Maximum Altitude
a
Measured from a 30 cm (12 in) radius surrounding the center of the enclosure
b
Non-condensing
Section 4.4

Mechanical Specifications

Weight
Ingress Protection
Enclosure
Section 4.5

IDU to ODU Cable Specifications

IDU to ODU Cable
Applications
General Construction
24
54 dB
1024/512FFT
QPSK, 16-QAM, 64-QAM
-20 to 100 dBm
-20 to 27 dBm
-40 to 75 °C (-40 to 167 °F)
-40 to 75 °C (-40 to 167 °F)
b
5% to 95%
2000 m (6562 ft)
1.5 kg (3.3 lb)
IP67
Aluminum
Outdoor installations, fixed or portable installations, digital distribution frames in transmission stations,
outdoor installations in harsh environments.
Custom made cable designed specially for wireless systems, meeting the requirements of Cat. 5e per
ANSI/TIA/EIA-568-B.2 and IEC 61156-5. The cable contains 4 twisted pairs, cabled, foil-tape shielded and
jacketed with two special black UV resistant, flame retardant PVC compounds for direct outdoor use in
harsh electrical environments. The diameter of the inner core complies with RJ45 connecting hardware
allowing direct connection to equipment without patch cords.