Siemens RUGGEDCOM WIN5237-IS Installation Manual page 23

Table of Contents

Advertisement

RUGGEDCOM WIN5237-IS
Installation Guide
Figure 10: Bending the Drain Wire
1. Foil    2. Drain Wire    3. Twisted-Pair Wires
5.
Partially untwist each wire pair, making sure to retain a half twist at the end.
Figure 11: Untwisting the Wire Pairs
6.
Arrange the wires according to the following pin-out description:
Figure 12: CAT-5e PoE Cable Pin-Out
1. Pin 1    2. Pin 8
7.
Slide the wires into the loading bar and then pull the loading bar down until its face is 16 mm (0.63 in) from
the wire jacket. If necessary, use pliers to hold the wires while pulling the loading bar.
Assembling the PoE Connector
1
3
Pin
Number
2
1
2
1
3
4
5
6
7
8
Installing the Subscriber Unit
2
Color
White/Orange
ETH Data
Orange
ETH Data
White/Green
ETH Data
Blue
White/Blue
Green
ETH Data
White/Brown
Brown
Chapter 2
Description
TP0+
TP0-
TP1+
48 V
TP2+
48 V
TP2-
TP1-
RTN (-)
TP3+
RTN (-)
TP3-
17