Multi-door networking controller

Advertisement

Quick Links

AR-716EV2
AR-716Ei
Multi-door Networking Controller
(RS-485)
(10 Base-T)
User's Guide
Version: 7.2
May 6, 2004

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR-716EV2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Soyal AR-716EV2

  • Page 1: Introduction

    AR-716EV2 (RS-485) AR-716Ei (10 Base-T) Multi-door Networking Controller User’s Guide Version: 7.2 May 6, 2004...
  • Page 2: Table Of Contents

    5.4.2 Get IP address by DHCP Server --------------------------------- 13 5.4.3 Get IP address by AR-801CM (COM Port) connects to PC --------------------------- 16 Installation diagram --------------------------------------------------------------------------------------- 19 AR-716Ei and AR-721H networking installation --------------------------------- 19 AR-716EV2 and AR-721H networking installation --------------------------------- 20 Points for attation --------------------------------------------------------------------------------- 21...
  • Page 3: Software Setting

    3. Software Setting 3.1 701 Server software setting of external weigand reader How to enter? Step1: Click the 701 Server Icon twice to access the Server on the down right corner of the windows. Step2: Click Tool Bar Icon (701E parameter) for the windows. Step3: Enter networking controller node ID, then click “Read”.
  • Page 4: Di Input V.s. Relay Output Connection Setting Of 701E Parameter

    RELAY RELAY RELAY RELAY DI.4 DI.3 DI.2 DI.1 3.3 DI Input V.S. Relay Output Connection setting of 701E Parameter 1. The DI.2 is exit button input of reader port 1 and the K1 is open door relay. (1) Choose “DI 2” under the menu item. (2) Click “K1”.
  • Page 5: Ar-716E-Io Software Setting

    Step3: Press [ Write ]. 4.2 AR-716E-IO hardware installation Step1: Take away each screw on the top left and on the down left of AR-716EV2 \ 716Ei PCB board. Step2: Screw copper column to fix AR-716E-IO PCB board. Step3: Then, screw tightly copper column by using screw before take away.
  • Page 6: Push Button & Lock Installation

    4.3 Push Button & Lock installation I O - E X P E N D CN 1 R E L A Y R E L A Y C O M R E L A Y R E L A Y CN 2 R E L A Y C O M...
  • Page 7: Ar-727I Configuration

    5. AR-727i Configuration 5.1 Reset to Factory Default of the AR-727i Press RESET button more than 5 seconds, then AR-727i will restore to Factory Default value. IP Address : 192.168.001.127 Gateway IP : 192.168.001.254 Subnet Mask : 255.255.255.000 Serail Port : 9600,N,8,1 TCP Port : 1621...
  • Page 8: How To Set Ip Address On The Ar-716Ei

    5.4 How to set IP address on the AR-716Ei 5.4.1 Get IP address by using Net727i software Usually, the network of some company don’t built-in the DHCP Server. Therefore, we can use the following method to get default IP address and modify it. The steps as follows: Step 1: Press RESET button more than 5 seconds, The BUSY LED will flash 5 times, then AR-727i will restore to Factory Default value.
  • Page 9 Step 4: Click ”Use the following IP address” and enter IP address 192.168.001.64, Subnet mask 255.255.255.0 Step 5: Click “ok” to exit. Step 6: Install Net727i.exe into your PC and run Net727i.exe (Start → Programs → soyal software → Net727i...
  • Page 10 Step 7: Click “Get” to get default Local IP Address, Gateway, Netmask and TCP Port. Step 8: Change new address and parameters then click “write”. Step 9: switch DIP SW-1 and SW-2 to “OFF” position. Remark: (1) How to know PC’s IP Address? (Win98) Start →...
  • Page 11 Setting Value Notes Necessity Local IP Address 192.168.001.127 Defines own IP Address of the Required AR-727CM Local Gateway IP 192.168.001.254 Defines the IP Address of the default Required Address gateway Required Local Subnet Mask 255.255.255.000 Defines the IP Address range for the local network segment Required TCP Port...
  • Page 12: Get Ip Address By Dhcp Server

    5.5.2 Get IP address by DHCP Server: AR-727i support Auto Configuration of the IP and gateway addresses and subnet mask function, but must make sure the DHCP Server is active. The steps as follows: Step 1: Power off. Step 2: PCB diagram as follows by using DHCP Function. Switch DIP SW-1 to “ON”...
  • Page 13 Step 10: Click “Hyper-Terminal”. Step 11: key-in any temporary name. Shown as follows: It is not important matter. Step 12: Choose which COM port that Step 13: Set Port Settings to 9600, 8, None, 1, AR-801CM connect and click OK to exit. None and click “OK”...
  • Page 14 Step 14: AR-727i already gets IP address now shown as follows: Note that save it after set all parameters. Step 15: Power off. Then switch DIP SW-2 to “OFF” position, take away communication IC Chip on the U3 position of the PCB and AR-801CM.
  • Page 15: Get Ip Address By Ar-801Cm (Com Port) Connects To Pc

    5.5.3 Get IP address by AR-801CM (COM Port) connects to PC At first, PCB diagram as follows and Connect AR-801CM to the HOST of the PCB: Switch DIP SW-1 to “OFF” position. Switch DIP SW-2 to “ON” position. (Serial Setup Mode) Switch Jumper J3, J4 and J5 to RS-485 position.
  • Page 16 Step 1: To modify parameter on the AR-727i through the Hyper-Terminal function of the Window. (Start → Programs → Accessories → Communication → Hyper Terminal) Step 2: Click “Hyper-Terminal”. Step 3: key-in any temporary name. Shown as follows: It is not important matter. Step 4: Choose which COM port that Step 5: Set Port Settings to 9600, 8, None, 1, AR-801CM connect and click OK to exit.
  • Page 17 Step 6: AR-727i already gets IP address now shown as follows: Step 7: Please refer above item and enter item on the so that set all parameters. Step 8: Note that enter item 6 on the to save parameter after finishing to set parameter. Step 9: Then switch DIP SW-1 and SW-2 to “OFF”...
  • Page 18: Installation Diagram

    6. Installation diagram 6.1 AR-716Ei and AR-721H networking installation...
  • Page 19: Ar-716Ev2 And Ar-721H Networking Installation

    6.2 AR-716EV2 and AR-721H networking installation...
  • Page 20: Points For Attation

    6.3 Points for attention 1. Please use the following installation method, it is correct. 801CM Controller Controller Reader 2. Don’t use the following installation method, it will cause communication error. 801CM Controller Controller Reader 3. We suggest using the following cable in RS-485 communication Please screw snake net on the controller.