User Operation; Alarm Display; Trouble Display - Paradox MG5000+ Installation Manual

32-zone wireless security systems
Table of Contents

Advertisement

MG5000+ / MG5050+ Installation Guide

User Operation

Alarm Display

If an alarm has occurred on a zone, the respective zone LED will flash, the [
continue to flash until disarming even if the zones are restored. To exit this mode and switch to live display mode before disarming, press the [
system is disarmed, the zones' LEDs will turn off, while the [
alarm. The alarm memory will be erased when the next alarm occurs and after a valid code is entered or upon full-arming the system.

Trouble Display

]
Press the [
key to view the Trouble Display. Please note that the keypad can be programmed to emit a
TBL
[
]
has occurred. Press the
key to stop the beeping.
TBL
To view the sub-menu, press the corresponding key in the main menu.
Main Menu Trouble
[1] Wireless zone low battery
[2] Power trouble
[3] Bell trouble
[4] Communication trouble
[5] Tamper and zone wiring failure
[6] Module tamper trouble
[7] Fire loop trouble
[8] Timer loss
[9] Wireless zone supervision loss
[0 (10)] or [10] Module supervision loss
[16] Keypad fault (K32+)
[
] Keypad fault (K10V/H only)
SLEEP
] key will light up, and the zones will be stored in memory. These respective LEDs will
MEM
] key remains lit. Press the [
MEM
MEM
Sub-Menu Trouble Menu
[1] to [32] Zones in low battery
[1] Low/No battery on the control panel
[2] AC failure on control panel
[3] Auxiliary overload on control panel
[4] Wireless keypad AC failure
[5] Wireless keypad battery failure
[6] Wireless repeater AC failure
[7] Wireless repeater battery failure
[1] Bell disconnect on control panel
[2] Bell overload on control panel
[1] Telephone Line Monitoring on control panel
[2] Fail to communicate on Monitoring Telephone 1 on control panel
[3] Fail to communicate on Monitoring Telephone 2 on control panel
[4] Fail to communicate on pager telephone on control panel
[5] Fail to communicate on voice telephone on control panel
[6] Fail to communicate with PC on control panel
[1] to [32] Zones in tamper and zone wiring failure
[
] Panel tamper
STAY
[1] 2WPGM
[2] Keypad bus
[3] ZX8/ZX82 Bus Module
[4] RTX3 Bus Module
[5] Wireless keypad
[1] to [32] Zones in fire loop trouble
[1] to [32] Zones in supervision lost6
[
] RF interference trouble
STAY
[1] 2WPGM
[2] Keypad bus (Panel reset will not clear this trouble, clear it in
section [955])
[3] ZX8/ZX82 Bus Module
[4] RTX3 Bus Module
[5] Wireless keypad supervision failure
[6] Wireless repeater supervision failure
] key to illuminate the LEDs corresponding to the zones that were in
beep
every 5 seconds whenever a new trouble condition
] key. Once the
CLEAR
51