8. SAFETY CARD RUNNING

8.1. BOTH GREEN LIGHTS ARE ON
Defect
Normal running with
remote control activated
(accelerated engine)
8.2. THE LOWER RED LIGHT IS ON
Defect
Opened hopper strainer
Electrical problem
P22
User manual - X-PRO D200
To check
-
To check
The position of the strainer.
The circuit must be cut somewhere.
The safety sensor of the hopper strainer
must be incorrectly positioned.
The safety sensor of the hopper strainer
does not function.
The remote control is defective.
HOPPER: REVERSE GEAR
HOPPER: FORWARD GEAR
Remedies
-
Remedies
Put the strainer back to its low position.
Contact technical service.
Check the correct alignment of both
safety sensor parts of the strainer.
Contact technical service.