Tab.1
Indoor unit
Outdoor unit
Capacity (cooling) BTU (kW)
Capacity (heating) BTU (kW)
Rated power consumption (cooling) (W)
Rated power consumption (heating) (W)
Power supply V/Hz
Rated power current (cooling/heating) A
Air circulation (indoor unit) m3/h
Air circulation (outdoor unit) m3/h
Noise level (indoor unit) dB(A)
Noise level (outdoor unit) dB(A)
Refrigerant
Energy eiciency (cooling/heating)
EN
Electrical protection class
Degree of protection against moisture
(indoor unit)
Degree of protection against moisture
(outdoor unit)
Refrigerant piping, Liquid side / Gas side, (inch)
Max. refrigerant pipe length, m
Maximum diference in level, m
Filling of Freon, g
Operating temperature range: cooling, ° C
Operating temperature range: heating, ° C
Net weight, indoor unit (kg)
Net weight, outdoor unit (kg)
Gross weight, indoor unit (kg)
Gross weight, outdoor unit (kg)
Net dimensions, indoor unit (mm)
Net dimensions, outdoor unit (mm)
Packing dimensions, indoor unit (mm)
Packing dimensions, outdoor unit (mm)
Electric air conditioner (split system)
H-AR8-09H-UI139/I
H-AR8-12H-UI140/I
H-AR8-09H-UI139/O
H-AR8-12H-UI140/O
9207 (4945~10912) /
11253 (4774~3520)/
2,7 (1,45~3,2)
3,3 (1,4~3,52)
9548 (4774~11253) /
11935(3751~12788)/
2,8 (1,4~3,3)
3,5 (1,1~3,75)
1028(450-1500)
820(380~1350)
776(380~1540)
969(400-1350)
220- 240~/50
~
220-240~/50
3.57(1.5~5.9)/
4.5(2.0-7.5)/
3.37(1.7~6.7)
4.22(1.6-7.0)
420
530
2500
2500
27/30/33
34/37/40
52
52
R410A
R410A
A/A
A/A
I class
I class
IPX4
IPX4
IPX4
IPX4
1/4 / 3/8
1/4 / 3/8
15
15
10
10
830
700
16°~24°
16°~24°
24°~ 32°
24°~ 32°
8,0
7,5
26,0
24,0
9,0
8,5
26,0
28,0
700×285×188
700×285×188
720×540×260
720×540×260
750x355x260
750×355×260
835×600×350
835×600×350