Operation mode
AUTO : The POWER indicator blinks at the initial stage.
The unit will select an operation mode every 10 minutes depending on the setting and room
temperature.
HEAT : The POWER indicator blinks at the initial stage. The unit will take some time to warm up.
COOL : Provides effi cient comfort cooling to suit your needs.
DRY
: Operates at low fan speed for a gentle cooling operation.
Energy saving temperature setting
You may save energy when operating the unit within the recommended temperature range.
HEAT : 20.0 °C ~ 24.0 °C / 68 °F ~ 75 °F.
COOL: 26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air fl ow direction
In COOL/DRY mode:
The horizontal fl ap is fi xed at middle position setting.
Once the temperature is achieved, the horizontal fl ap swings up/down automatically.
In HEAT mode:
If AUTO is set, the horizontal fl ap is fi xed at the predetermined position. The vertical fl ap swings
left/right after the temperature rises.
In COOL/HEAT/DRY mode:
The horizontal fl ap swings up/down automatically.
Auto restart control
When power is resumed after a power failure, the operation will restart automatically with the last
operation mode and airfl ow direction.
• This control is not applicable when TIMER is set.
nanoe™X filter deactivation
Depending on the unit's accumulated operation time, the nanoe™X may be activated only once a day
after the unit is turned off standby mode. During the nanoe™X filter deactivation operation, the flap will
open slightly with low fan speed operation for 2.5 hours if the unit was in COOL/DRY mode, and 2 hours
if the unit was in nanoe™ TECHNOLOGY, before the unit is turned off. This is to remove viruses/bacteria
from the surroundings.
The filter deactivation operation is complete when the fan stops and the flap closes. Do not turn off the
power supply during this operation. After a power failure, this operation will not resume.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Max.
COOL
Min.
Max.
HEAT
Min.
DBT: Dry bulb temperature, WBT: Wet bulb temperature
32
Indoor
DBT
WBT
32 (89.6)
23 (73.4)
16 (60.8)
11 (51.8)
30 (86.0)
16 (60.8)
DBT
46 (114.8)
16 (60.8)
-
24 (75.2)
-
-5 (23.0)
Outdoor
WBT
26 (78.8)
11 (51.8)
18 (64.4)
-6 (21.2)