Pantron IMX-N830 Operating Instructions Manual page 8

8-channel light barrier multiplexer
Table of Contents

Advertisement

Available languages

Available languages

GB
Operating Instructions
8-channel light barrier multiplexer IMX-N830
5.
Connections
Wires are connected with two rows of 23 terminals (see
picture 1).
1
3
5
7
9
2
4
6
8
8-CHANNEL INFRARED MULTIPLEXER
25
27
29
31
24
26
28
30
32
picture 1: Number of terminals
Ground
Schwarz
Rot
Rot
Rot
Schwarz
Schwarz
Schwarz
from
Master
IR-Transmitter
picture 2: Wiring diagram
5.1
Voltage supply
1
Before connecting the multiplexer, look on the side and
check if the power supply is the same as the connection
value. The power supply will be connected on the terminal
no. 22 and no. 23 (see picture 1).
For devices with direct current, terminal no. 22 is positive
and terminal no. 23 is neutral.
24V DC to be provided by a suitably rated UL Listed Class
2 power supply.
Caution!
The AC-supply devices are isolated from main. A grounded
connection on the low voltage side is required.
In synchronized operation of multiple devices (master/slave),
we recommend installation using short connecting cables.
1
Inscription front label
2
Core coding transmitter cable
3
Core coding receiver cable
8
/12
11
13
15
17
19
21
23
10
12
14
16
18
20
22
SW
FUNCTION
ON
OFF
1
Transmit Power
100% 20%
2
Multiplex-Speed
low
high
3
Relay1= Curtain
yes
no
4
Delay Timer
0-15s off
33
35
37
39
41
43
45
34
36
38
40
42
44
46
Power supply
Transistor outputs
V. SUPPLY
Rot
Gelb
Gelb
Gelb
Gelb
Schirm
Schirm
Schirm
Schirm
following
slave device
1
2
3
4
5
6
7
8
IR-Receiver
5.2
Transmitter (IT...)
Four infrared transmitters can be connected to one 8-channel
multiplexer. Connect the transmitters as shown in table 1.
Transmitter
Plus (red)
1
No. 3
2
No. 2
3
No. 27
4
No. 28
5
No. 30
6
No. 31
7
No. 33
8
No. 34
table 1: Transmitter terminals
5.3
Receiver (IR...)
1
Four infrared receivers can be connected to one 8-channel
multipexer. Connect the receivers as shown in table 2.
Receiver
Plus (yellow)
1
No. 36
2
No. 37
3
No. 39
4
No. 40
5
No. 42
6
No. 43
7
No. 45
8
No. 46
table 2: Receiver terminals
5.4
Transistor output
The multiplexer has one transistor
output per channel (connection
diagram in table 3), switchable as a
PNP- or NPN output. All outputs have
a common plus- (Pin 9) and ground-
connector (Pin 7).
The current capacity is maximal 100
mA with a external voltage between
12 V DC and 30 V DC (see picture 3).
Channel
Transistor outputs
1
No. 6
2
No. 8
3
No. 10
4
No. 12
5
No. 14
6
No. 16
7
No. 18
8
No. 20
table 3: Output terminals
1
Ground (black)
2
No. 1
No. 1
No. 26
No. 26
No. 29
No. 29
No. 32
No. 32
Ground (shield)
3
No. 35
No. 35
No. 38
No. 38
No. 41
No. 41
No. 44
No. 44
R
i
R
i
picture 3: Transistor
output
2
3
P/N +
P/N 1...8