Important information for the installer
▪This appliance may only be installed by a gas installer
registered with the South African qualification and
certification committee (SAQCC).
▪The appliance must be installed in accordance with the
requirements of SANS 10087-1 for use with LPG, SANS
827 for use with NG and any fire department regulations
and/or local bylaws applicable to the area. If in doubt,
check with the relevant authority before undertaking the
installation.
▪Upon completion of the installation you are required to
fully explain and demonstrate to the user the operational
details and safety practices applicable to the appliance
and the installation.
Moving the appliance by the gas line or door handle
Do not move the appliance while holding the gas line;
the gas pipe could be damaged. There is a risk of a gas
leak! Do not move the appliance while holding it by the
door handle. The door hinges and door handle could be
damaged.
Appliance categories
Country
Category
RU, BY, KZ, AM, KG
II 2H3B/P
UA
II 2H3B/P
MA
I 3+
AE, LB, JO
II 2H3B/P
EG
II 2H3+
Electrical connection
Only licensed specialists may connect the appliance.It
is important that you comply with the requirements of
your electricity supplier.
The appliance is designed to operate at 220-240 V. A
16 A fuse is required for connection.
Any damage arising from the appliance being
connected incorrectly will invalidate the warranty.
Caution!
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The appliance must be disconnected from the power
■
supply whenever installation work is being carried
out.
The appliance fulfils the requirements of protection
■
class I and may only be connected to an earthed
socket.
P (mbar)
2000 тта–3000 тта
20 - 28 - 30
28 - 30/37
20 - 28 - 30
20 - 28 - 30/37
Installation and connection
The mains power cable must be at least type
■
H05 V V-F 3G, 1.5 mm².
Notes
1
Yellow and green
2
Brown
3
Blue
:
Warning – Danger of death!
There is a risk of electric shock if you touch live
components.
Always make sure your hands are dry when you
■
touch or hold the mains plug.
Only pull out the mains cable by taking hold of the
■
plug and removing the plug; never pull it out by the
mains cable itself, as this could damage it.
Never unplug the mains plug when the appliance is
■
in operation.
Please note the following information and ensure that:
Notes
The mains plug fits the socket.
■
The cable cross section is adequate.
■
The earthing system is properly installed.
■
The mains cable is only replaced by a qualified
■
electrician (if this is necessary).Spare mains cables
can be ordered from our after-sales service.
No power strips/multi-way connectors or extension
■
cables are used.
If using a residual current device, only use one that
■
bears the mark
.
z
The presence of this mark is the only way to be sure
that it fulfils all the applicable regulations.
The mains plug can be accessed at all times.
■
The mains cable is not kinked, crushed, modified or
■
severed.
The mains cable does not come into contact with
■
heat sources.
en
9