30
English
Problem
The 'ready to flash' light
does not light up white.
The device produces a
strange smell.
The device does not
flash, the fan is not
switched on and all 5
intensity lights blink.
Possible cause
The device is not
completely in contact with
your skin.
The light exit window or
the SmartSkin sensor is
dirty.
You have not removed the
hairs on the area to be
treated properly. These
hairs may get burned and
can cause the smell.
The attachment is not
attached properly.
Solution
Place the device at a 90 degree angle on the
skin so that the integrated safety system in in
contact with your skin.
Clean the light exit window and the SmartSkin
sensor carefully.
Pretreat your skin before you use Lumea.
Make sure you attach the attachment
completely. If necessary, clean the electronic
contacts on the attachment.