TAKACAT T240L Owner's Manual

TAKACAT T240L Owner's Manual

Advertisement

Owners Manual – T240L + T280L:
680mbar. The Halkey-Roberts valve must be set to inflate, meaning the valve mechanism must pop
out a bit. When inflating, always press the ground slightly on the sides.
3.
Inflate the included seat with 200mbar, position it where you need it. You can fixed it at the inside
rings.
4. Finaly the two oars must be assembled and mounted on the oarlocks and be fixed at the end.

Maintenance:

Regularly check valves, stitching, ribbons, hooks, screws and nuts on your Takacat boat. Pontoons are more
alive than a plastic hull and their constant movement can cause fatigue damage. It is important to keep the
pontoons sufficiently inflated. Under-inflation will cause more water resistance and thus slowing. Regularly
check the pontoon mounts to the transom and hull and other joints in the tubes. In smaller inflatables
between any loose floorboards and pontoons, it is important to keep areas clean from dirt and debris that
could rub and wear down the pontoon.
Cleaning basically requires no more than a cleanser, a brush and a sponge for managing the cleaning and
maintenance of the boats pontoons.
Soap: Mix the soap with water according to instructions on the package. Scrub the pontoons with a sponge
or scrubbing brush. Rinse off with water. Never use high pressure when cleaning the boat, it can damage
the stitches or fabric of the pontoons, etc.
© TAKACAT – Friedel Hacker (Dipl.-Ing.)
Boat Manufacturer:
AIR YACHT Ltd. - 3 Owens Rd, Epsom - Auckland 1023 -
Neuseeland - www.takacat.com
Please note the information given on the rating plate
attached on the transom plate and the information
on the inside of the tubes.
All Takacats are designed for short shaft engines.
Outboard motors with long shafts or extra long shafts
must not be used.
Assemply boat:
1.
Firstly the both catamaran tubes must be inflated to
220mbar. Maximum pressure is 250mbar. The Halkey-
Roberts valve must be set to inflate, meaning the valve
mechanism must pop out a bit.
2.
Place the high-pressure floor precisely between the
tubes and the transom area. The correct position is
obtained when the two fixing/trailing rings can be
passed at right angles through the two slots of the
connecting floor. Inflated the high-pressure floor to a
minimum of 600mbar. The maximum pressure is
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T240L and is the answer not in the manual?

Questions and answers

Summary of Contents for TAKACAT T240L

  • Page 1 4. Finaly the two oars must be assembled and mounted on the oarlocks and be fixed at the end. Maintenance: Regularly check valves, stitching, ribbons, hooks, screws and nuts on your Takacat boat. Pontoons are more alive than a plastic hull and their constant movement can cause fatigue damage. It is important to keep the pontoons sufficiently inflated.
  • Page 2 Storage: TAKACAT Sport or Lite inflatables can be stored either inflated or in a storage case. When stored in a bag, the bag must be dry. Take this opportunity to clean sand etc. from between the floorboard and pontoons. When it comes to winter, there are some basic tips. The boat does best not to stand in freezing temperatures, although it is not a must to have it indoors.
  • Page 3 The specifications of the products which TAKACAT distributes and / or offers as a dealer were taken over by the respective manufacturer. TAKACAT accepts no liability for their accuracy. Maximum figures apply under optimal conditions (environment, system configuration, software, etc.).
  • Page 4 General Importer: TAKACAT GmbH Leibnizstraße 3 53498 Bad Breisig (Germany) Tel.: +49 2633-200360 Fax: +49 2633-200361 Email: info@takacat.de Web: www.takacat.de © TAKACAT – Friedel Hacker (Dipl.-Ing.) Page 4...

This manual is also suitable for:

T280l

Table of Contents