Page 1
PM450 User Manual The Point Mobile name and logo are trademarks of Point Mobile Co., Ltd. in Korea and many other countries. All rights reserved. This document and any enclosed documents contain confidential or privileged information belonging to Point Mobile and/or its affiliates. You are hereby notified that any disclosure, copying, distribution...
1. Introduction Thank you for purchasing PM450 handy terminal. This manual generally provides you with the safety information and basic features and operations of the PM450 device. Please read all safety precautions and this manual carefully before using your handy terminals and peripherals to ensure safe and proper use. Trademarks The official name of Windows XP is Microsoft Windows XP Operating System.
PM450 handy terminal contains the following items basically: • Handy terminal • 5V/2A AC Adaptor • AC Plugs • Battery Pack • Stylus Pen and tether • Hand strap • LCD Screen Protection Film ☞ NOTE: Keep the original packaging for use when sending products to the technical assistance center. Damage caused by improper packaging is not covered under the warranty ☞...
Do not attempt to disassemble the PM450 handy terminal, as it does not contain parts that can be repaired by the user. Any tampering will invalidate the warranty. When replacing the battery pack or at the end of the operative life of the PM450 handy terminal, disposal must be performed in compliance with the laws in force in your country.
Page 8
staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even though reflective surfaces such as mirrors, etc. The laser light is visible to the human eye and is emitted from the window indicated in the figure. ATTENTION Un laser de classe 2 reste inoffensif pour les yeux.
For installation, use and maintenance, it is not necessary to open the device. WARNING: Do not attempt to open or otherwise service any components in the optics cavity. Opening or servicing any part of the optics cavity by unauthorized personnel may violate laser safety regulations. The optics system is a factory only repair item.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur. Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé...
WEEE Compliance 2.11. Information for the user in accordance with the European Commission Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on Waste Electrical and Electronic Equipment (WEEE) This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed.
3. Replace the battery door to start from bottom to top door’s lock downwards. ☞ NOTE: Two points of Battery guide stopper must be pertinently inserted to rear cover battery guide stopper hole ☞ NOTE: The battery door must be installed prior to booting the unit. WARNING: Use only Pointmobile-approved Li-Ion battery packs.
Page 14
Handy Terminals ship with only main battery pack significantly charged of power. Charge the main battery pack with the Handy Terminal charging cable for a minimum of 4 or 6 hours depending on your battery before initial use. 3.2.1 Charging with DC Adaptor a.
DO NOT attempt to charge damp/wet handy terminals or batteries. All components must be dry before connecting to an external power source. Batteries must be charged at a temperature ranging from 0~45℃ (±3℃). If you don’t follow the guide, it might have a harmful effect on the battery life.
Page 16
By default, the battery pack is disconnected at the factory to avoid damage due to excessive draining. Annual replacement of rechargeable battery pack avoids possible risks or abnormalities and ensures maximum performance. WARNING: DO NOT attempt to charge damp/wet handy terminals or batteries. All components must be dry before connecting to an external power source.
WARNING Do not short-circuit the battery pack contacts connecting the positive terminal and negative terminal. This might happen, for example, when you carry a spare battery pack in your pocket or purse; accidental short–circuiting can occur when a metallic object such as a coin, clip, or pen causes direct connection of the contacts of the battery pack (these look like metal strips on the battery pack).
If you apply the power to your device, it turns on by itself. Do NOT press any keys or interrupt while turning on process. When the process is complete, the Desktop appears, and the terminal is ready for use. Desktop 3.6.
Shows the volume Indicates the Battery Control Panel (CPL) Indicates Clock & Alarm CPL zoom in/ out Access the Bluetooth radio Left and right arrows are used to scroll through additional icons Icon Meaning Indicates AC connection mode Indicates WAN (Phone) connection mode Indicates Sound connection mode Indicates LAN / Bluetooth mode Indicates Keypad mode (Numeric)
Pop-Up Menus 3.10. You can quickly choose an action for an item using the pop-up menus. 1. Tap and hold the stylus on the item name. The pop-up menu appears. 2. Lift the stylus and tap the action you want to perform. The contents of pop-up menus change according to the program you are using.
GPRS/EDGE : Quad band, 850/900/1800/1900MHz (Data Communication Only) UMTS/HSPA+: Five band, 800/850/900/1900/2100MHz GPS: Standalone and Assisted GPS Front Panel Layout 4.3. Touch screen display Scan key Keyboard (57-key Keyboard Alpha-numeric) (34-key numeric) LED Indicator Shows the information needed to operate your device as follows: Note: The LED is user-programmable.
Side and Bottom Left / Right Light at the side and bottom of the terminal when a scan fails Blue Light at the side and bottom of the terminal when a scan pass. Keypad 34 numeric keypad (including side scan power button). 57 Alpha-Numeric keypad (including side scan, power button).
☞ NOTE: Using the backlight option while on battery power substantially reduces battery life. You may make the same changes when on external power by tapping the External tab. Keypad Backlight 4.5. To turn on the keypad backlight, check the checkbox. The duration of backlight of keypad synchronizes with LCD backlight’s.
Page 24
Clean the touch panel thoroughly with a clean, non-abrasive, lint-free cloth, Make sure nothing is on the touch panel. Blue tag with backing film: Peel off this mask before application. Align the exposed edge of the screen protector along the left edge of the touch panel. Make sure that it lies flush with edges of the touch panel.
Page 25
6. Press gently but firmly. Use the card a necessary to smooth out any air pockets or bumps after allocation Press the Power key to weak the terminal and check the touch panel with the stylus.
Page 26
Verify that the screen accepts input from the stylus as usual. If not, re-apply the screen protector. Press the Power key to put the terminal back in suspend mode. 10. Clean the surface of the screen protector with a clean, non-abrasive, lint-free cloth. 11.
Wrist Lanyard The HANDY TERMINAL comes with Wrist Lanyard. You can attach it to the device. Hand strap The HANDY TERMINAL comes with Hand strap. You can attach it to the device. Finger Saddle This is a slightly depressed and angled area of the back housing that is designed to cradle or “saddle”...
Side Button You can using the scan using the Scan button. Installing Memory Cards 4.10. The HANDY TERMINAL supports Micro Secure Digital (SD) memory cards up to 32GB. Sandisk, Kingstone and ATP micro SD recommended To access the Micro SD card slot and insert the card, proceed as follows: 1.
Side Button You can use the Programs Buttons option in the Control Panel to change the functionality of the side buttons. Scan function is assigned by default (Scan button). EarJack 3.5pi 4pole Jack. This connector supports Ear-Mic headset Top Panel Layout 4.12.
HandyLink Connector The HandyLink mechanical connector is designed to work exclusively with HANDY TERMINAL peripherals and cables. This connector powers the terminal, charges the main battery, and facilitates communication. This connector supports High speed USB 2.0 communication (up to 480 Mbps) Through this connector, you can communicate with a host workstation via Microsoft ActiveSync;...
Ethernet port. For more information, see Single Slot cradle/Single Ethernet cradle Device on paragraph 12. Li-ion Battery Packs 4.15. The Li-ion battery pack provides the main power supply for the terminal. Battery Power 4.16. The intelligent battery technology inside the terminal features of battery power: •...
Main battery pack Charging Options When the battery is installed in the terminal, you can use any of the peripherals listed below to charge the battery. • AC Power Supply to DC Jack Port direct. • Single slot docking cradle/Single slot Ethernet cradle •...
☞ Start -> Settings -> System -> Power NOTE: You can also check battery power by tapping Resetting the Terminal 4.19. There are three types of system resets: a Soft Reset, a Hard Reset, or a Factory Reset. The soft and hard resets preserve all data stored in the file system.
To perform a Hard Reset if the terminal has stopped responding, press and hold the Power button for 8 seconds until the terminal starts to re-boot. Factory Reset CAUTION: To prevent data loss, back up all user data to an SD card or external memory device before performing an upgrade or factory reset.
PM450 Technical Specifications 4.23. Model PM450 Windows Embedded CE 6.0 Professional Operating System Windows Embedded Handheld 6.5 Professional Application Software Tools and Demos Processor Cortex-A8 1GHz Memory 512MB RAM X 1GB Flash Storage Expansion User accessible Micro SD memory card slot 240 x 320 pixels QVGA (Transmissive) Display 480 x 640 pixels VGA (day light readable) - option...
Basic Keys 5.3. Name Function BLUE Modifies the next key pressed to type specific functions. Yellow Toggles the keypad between alpha (upper and lowercase) and numeric modes. (Numeric Key) Indicator changes accordingly on the command bar. Yellow Toggles the keypad between normal and ctrl modes. Indicator changes accordingly (Alpha-Numeric on the command bar.
Numeric mode. Normal/Ctrl Modes of Numeric Keypad 5.5. The keypad defaults to normal mode. Use the YELLOW key to toggle between normal and ctrl modes. Pressing the YELLOW key once locks the keypad in normal mode, ctrl mode. The command bar on the screen displays an icon that indicates the normal/ctrl status of the keypad. Icon Keypad Status Normal mode.
Page 39
BLUE + F11 BLUE + F12 BLUE + 1 Volume Up BLUE + 4 Volume Down BLUE + 3 Backlight Up BLUE + 6 Backlight Down BLUE + 5 Page Up BLUE + 0 Page Down BLUE + 1 Home BLUE + 9 BLUE + ENT BLUE + TAB...
BLUE + A Volume Up BLUE + F Volume Down BLUE + E Backlight Up BLUE + J Backlight Down BLUE + H Page Up BLUE + R Page Down BLUE + L Home BLUE + N BLUE + SP Windows Manu BLUE + SHIFT Align the screen(Press ESC to exit)
No Action No Action No Action No Action No Action No Action No Action No Action No Action No Action No Action No Action (Alpha-Numeric only) No Action (Alpha-Numeric only) No Action (Alpha-Numeric only) No Action (Alpha-Numeric only) 6. Using the Image Engine Overview 6.1.
☞ NOTE: It may not read the barcode if it is blue on white background. Try again after changing angle or adjusting the brightness of the surrounding. ☞ NOTE: It may not read the barcode if it is black on silver background. Try again after changing angle or adjusting the brightness of the surrounding.
Codabar, Trioptic Code Interleaved 2 of 5, Aztec Code 2D Symbologies Codablock F Data Matrix MaxiCode MicroPDF417 PDF417 QR Code and Micro QR Code Han Xin OCR-A OCR Option OCR-B Australian Post Postal Codes British Post Canadian Post China Post Japanese Post Korea Post Netherlands(KIX) Pst...
4. Center the aimer crosshair over the bar code. The aiming beam should be oriented in line with the bar code to achieve optimal decoding; Omni-Directional Scanning Positions on paragraph 6.10. 5. When the bar code is successfully decoded, the decode LED lights green and the terminal beeps. Sample Bar Codes 6.9.
☞ New picture :N560X-IM RevC.pdf base. NOTE: ☞ NOTE: To achieve the best read, the aiming beam should be centered horizontally across the bar code. The aiming pattern is smaller when the terminal is held closer to the code and larger when the terminal is held farther from the code.
Page 47
☞ New picture :SE965HP – Integration Guide – Jan 2013 – 15156605a.pdf base. NOTE:...
Scanning Positions 7.9. The aiming beam must be aimed across the entire bar code to provide you with the best scanning performance. The aiming pattern is smaller when the terminal is held closer to the code and larger when the terminal is held farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit whereas larger bars or elements (mil size) should be read farther from the unit.
Menu Item Sub Item This item … Enables and disables the audio notification for decode/data Beep reception. There is one sound for success and another sound for an error. Notification Enables and disables LED notification for decode/data reception. Enables disables Vibrator notification decode/data...
Device ID 9.1.2. Your device uses this information to identify itself to other computers. Terminal Serial Number will be in Device Name section by default. You can modify it Copyrights 9.1.3. Portions of this software are based on NCSA Mosaic. Power properties 9.2.
Advanced tab 9.2.2. To adjust power management settings, 1. Set idle time when on battery power before device suspends. 2. Set idle time when on external power before device suspends. 3. To exit, press OK from the command bar, or press the < ENT > key on the keypad. ☞...
Chose its type: Default – button will be assigned default function. No function – button does not have any functions. Scan key – button is used as Scan key. Application – click on Open button and select application to bind with this key.
Battery power Tab 9.4.1. Modify display backlight settings when device runs on batteries. Set display brightness level Set backlight timeout time. Available options: 10 sec (by default) 30 sec 1 min 2 min 3 min 4 min 5 min ...
Scanner Settings 9.5. To change the Scanner configuration parameter as follows: Tap the Scanwedge icon in the System Tray to open the menu shown in image on the right and select Settings to open the Scanner Settings applet or Start > Settings > System > Scanner Settings...
Scanner Settings Applet 9.5.1. Section Option Description Specifies the trigger time out in seconds. If a barcode is not Trigger timeout (sec) decoded within the specified timeout, the default Notifier indicates that decoding is failed Enable Auto Scan with specified Enable Auto Scan interval.
Page 57
Start to decoding after specified Delay Before milliseconds Decoding(IT5300SR Values: 0(default), 100, 200, device only) 300, 400, 500, 4500, 700, 800, 900, 1000 Select Result Type User Message User Message Keyboard Event Clipboard(default) Wedge mode Select the desired barcode end method from the pull down list.
Section Option Description Tap/enable this checkbox to Enable this code enable the selected bar code type. Enter the desired features you Barcode ID wish to transmit as bar code ID Set the minimum and maximum lengths from the pull-down lists. If the numbers are the same, Length acceptable bar codes will only...
Installing Additional Software 10.2. Handy Terminal is shipped with the operating system, radio drivers, and custom software (CICO) already installed. These are the default programs that install when your terminal first boots up. You can install additional software programs on the terminal provided that the following parameters are met: •...
☞ NOTE: You can download the most current version of ActiveSync (for Windows XP) or Windows Mobile Device Center (Windows Vista, 7) from www.microsoft.com. WARNING: When communicating via ActiveSync, your terminal is designed to be connected to the host workstation with a Pointmobile communication peripheral. We recommend use of Pointmobile peripherals, power cables, and power adapters.
cradle. 2. The Handy Terminal automatically opens ActiveSync or Windows Mobile Device Center to establish a connection. Synchronizing with the Host Workstation 10.10. After setup, synchronization begins automatically whenever the terminal’s mechanical connector connects to a Handy Terminal peripheral that is connected to a host workstation with ActiveSync installed.
Adding Programs via ActiveSync 10.12. WARNING: When selecting programs, verify that the program and version of the program are designed for the Windows Embedded Pointmobile 6.5 Pro and the terminal’s processor. You can verify your processor by tapping Start -> Settings -> System -> About -> Version tab.
program is located. 4. Tap on the program file to install it. If you copied the file to the Autoinstall Cabfile folder, you can choose to install the program by performing a hard reset. The program installs as part of initialization. 5.
By default, the 802.11a/b/g/n radio is powered-off (i.e., disabled) “out of the box” To power it on (i.e., enable), press the vertical arrow (bottom right corner of screen) and select Turn Wireless LAN On. The enable/disable state of the radio will survive subsequent soft and hard resets. The next step is to configure the connection parameters of the radio to connect to a wireless network.
caused by other devices (microwave ovens, radio transmitters, etc.). Connecting to Other Devices 11.2. Before connecting to another device, make sure that the Bluetooth connection on the other device is enabled. 1. Tap on the Bluetooth icon in the task bar. The Bluetooth Handler appears on the screen.
Single Slot cradle except it supports Ethernet communication as well as full-speed USB 2.0 Battery Charging 12.2. The base should complete a full charge of the battery pack in 4 hours for the standard capacity 3120mAh: 450-BTSC pack on the handy terminal. . In addition to charging, the base powers the terminal’s intelligent battery charging system, which protects the battery from being damaged by overcharging.
12.5 Back Panel Single Slot Cradle Single Ethernet Cradle Ethernet port USB port DC power jack USB port DC power jack DC Power Jack Connect the power cable to this power jack; see powering the Single Slot Cradle Device on paragraph 12.6.
1. Attach the appropriate plug to the power adaptor. 2. Plug the power cable into the power source. 3. Plug the connector into the DC power jack on the back panel. The base is now powered. When a terminal is properly seated, the base powers the terminal, charges the terminal’s main battery pack, and launches ActiveSync (see ActiveSync Communication on paragraph 10.4).
Technical Specifications for Cradle 12.8. 450-SSC (Single Slot Cradle) Model 450-SEC (Single Ethernet Cradle) Structural Dimensions 135.5mm(L) x 116mm(W) x 81mm(H) Single Slot cradle - 315g Weight Single Ethernet cradle - 320g Material Polycarbonate Color Black Environmental Operating Temperature -20° to 50°C Storage Temperature -25°...
13. 4-Slot Battery Charger ☞ NOTE: The 4-Slot Battery Charger is option accessory and needed to purchase separately with incidental expenses in the aftermarket Overview 13.1. The 4-Slot Battery Charger device is a four-slot charging station that should charge up to four Li-ion battery Packs ( standard capacity 3120mAh : 450-BTSC, extended capacity 5200mAh : 450- BTEC ) in four hours(3200mAh) and six hours(5200mAh).
in a slot, it immediately begins charging and its Status LED lights. Rubber Feet The bottom panel has six rubber feet to stabilize the unit on a flat surface. You can set the charger on a dry, stable surface, such as a desktop or workbench near an electrical outlet. Charging LED If the LED is red, the unit is charging;...
WARNING: Do not short-circuit between each contact of the cradle. It may cause fire. : Provoquer un court-circuit entre les contacts de la station d’accueil, pourrait provoquer un incendie. AVERTISSEMENT Technical Specifications for 4-slot battery charger 13.6. Model 4SBC (4- Slot Battery Charger) Structural Dimensions 256mm(L) x 105mm(W) x 37mm(H)
Page 73
Air: ± 12kV Electrical Static Discharge Direct: ± 8 kV Humidity 95% humidity (non-condensing) Power Supply AC 100–240 Vac. Input (Universal) 50/60Hz 1.5A (from the power source) Included with Charger Output (to the cradle) DC 12V , 5A Charging Main battery: Standard Capacity:3120mAh (450-BTSC) – Approx. 4hours Standard Charge Extended Capacity : 5200mAh(450-BTEC) –...
Need help?
Do you have a question about the PM450G and is the answer not in the manual?
Questions and answers