2.4 ELECTRICAL & PHYSICAL DATA (SEE TABLE 1)
TABLE 1
ELECTRICAL AND PHYSICAL DATA – 13 SEER
Compressor
Model
Phase
Number
Rated Load
Frequency (Hz)
Amperes
Voltage (Volts)
(RLA)
Rev.1/10/2008
18
1-60-208-230
9/9
24
1-60-208-230
12.8/12.8
30
1-60-208-230
14.1/14.1
36
1-60-208-230
17/17
42
1-60-208-230
21.8/21.8
48
1-60-208-230
21.8/21.8
60
1-60-208-230
26.3/26.3
ELECTRICAL AND PHYSICAL DATA – 14 SEER
Compressor
Model
Phase
Number
Rated Load
Frequency (Hz)
Amperes
Voltage (Volts)
(RLA)
Rev.1/10/2008
18
1-60-208-230
9/9
24
1-60-208-230
12.8/12.8
30
1-60-208-230
14.1/14.1
36
1-60-208-230
17/17
42
1-60-208-230
17.9/17.9
48
1-60-208-230
21.8/21.8
60
1-60-208-230
26.4/26.4
NOTES:
Π20 Fins per inch [mm]
 Factory charged for 15 ft. [4.6 m] of line set
6
ELECTRICAL DATA
Fan Motor
Minimum
Full Load
Circuit
Locked Rotor
Amperes
Ampacity
Amperes
(FLA)
Amperes
(LRA)
48
0.6
12/12
58.3
0.6
17/17
73
0.8
19/19
96.7
1.2
23/23
112
1.2
29/29
117
1.2
29/29
134
1.2
35/35
ELECTRICAL DATA
Fan Motor
Minimum
Full Load
Circuit
Locked Rotor
Amperes
Ampacity
Amperes
(FLA)
Amperes
(LRA)
48
0.6
12/12
58.3
0.6
17/17
73
0.8
19/19
96.7
1.2
23/23
112
1.2
24/24
117
1.2
29/29
150
1.2
35/35

3.0 LOCATING UNIT

3.1 CORROSIVE ENVIRONMENT

The metal parts of this unit may be subject to rust or deterioration if exposed to a
corrosive environment. This oxidation could shorten the equipment's useful life.
Corrosive elements include, but are not limited to, salt spray, fog or mist in seacoast
areas, sulphur or chlorine from lawn watering systems, and various chemical conta-
minants from industries such as paper mills and petroleum refineries.
If the unit is to be installed in an area where contaminants are likely to be a prob-
lem, special attention should be given to the equipment location and exposure.
Avoid having lawn sprinkler heads spray directly on the unit cabinet.
In coastal areas, locate the unit on the side of the building away from the water-
front.
Shielding provided by a fence or shrubs may give some protection, but cannot
violate minimum airflow and service access clearances.
Elevating the unit off its slab or base enough to allow air circulation will help
avoid holding water against the basepan.
Regular maintenance will reduce the build-up of contaminants and help to protect
the unit's finish.
Fuse or HACR
Outdoor Coil
Circuit Breaker
Face Area
No.
Minimum
Maximum
Sq. Ft.
Rows
Amperes
Amperes
[m
2
] Œ
15/15
20/20
11.06 [1.03]
20/20
25/25
11.06 [1.03]
25/25
30/30
13.72 [1.27]
30/30
35/35
16.39 [1.52]
35/35
50/50
21.85 [2.03]
35/35
50/50
21.85 [2.03]
45/45
60/60
21.85 [2.03]
Fuse or HACR
Outdoor Coil
Circuit Breaker
Face Area
No.
Minimum
Maximum
Sq. Ft.
Rows
Amperes
Amperes
[m
2
] Œ
15/15
20/20
11.06 [1.03]
20/20
25/25
11.06 [1.03]
25/25
30/30
13.72 [1.27]
30/30
35/35
16.39 [1.52]
30/30
40/40
21.85 [2.03]
35/35
50/50
21.85 [2.03]
45/45
60/60
21.85 [2.03]
PHYSICAL DATA
Refrig.
Per
CFM
Net
Circuit
[L/s]
Lbs. [kg]
Oz. [g]
1
1700 [802]
91 [2580]
144 [65.3]
1
2370 [1118]
91 [2580]
130 [59]
1
2800 [1321] 101 [2863]
198 [89.8]
1
3575 [1687] 109 [3090]
215 [97.5]
1
3575 [1687] 150 [4252]
202 [91.6]
1
3575 [1687] 141 [3997]
205 [93]
1
3575 [1687] 228 [6464]
209 [94.8]
PHYSICAL DATA
Refrig.
Per
CFM
Net
Circuit
[L/s]
Lbs. [kg]
Oz. [g]
1
1700 [802]
91 [2580]
144 [65.3]
1
2370 [1118]
91 [2580]
130 [59]
1
2800 [1321] 101 [2863]
180 [81.6]
1
3575 [1687] 109 [3090]
215 [97.5]
1
3575 [1687] 150 [4252]
202 [91.6]
1
3575 [1687] 141 [3997]
205 [93]
2
3360 [1586] 259 [7343]
277 [125.6] 289 [131.1]
Weight
Shipping
Lbs. [kg]
152 [68.9]
138 [62.6]
208 [94.3]
227 [103]
214 [97.1]
217 [98.4]
221 [100.2]
Weight
Shipping
Lbs. [kg]
152 [68.9]
138 [62.6]
190 [86.2]
227 [103]
214 [97.1]
217 [98.4]

Hide quick links: